STORAGE
REMOVING FROM STORAGE
Be sure that the grade of oil in the engine crankcase is as specified in Engine Oil Selection in this manual.
A.Loosen the fuel tank drain plug and fuel filter cup, and be sure all water and sediment has drained from the fuel system before closing. Tighten the drain plug and replace the filter cup.
B.Check the level of the coolant in the radiator.
C.Check engine oil level.
D.Check hydraulic fluid level.
E.See that the battery is fully charged and that the terminal connections are clamped tightly.
F.On hydrostatic drive tractors, follow the same procedure for starting as Starting Procedure for Hydrostatic Drive Tractors after Transporting on truck or flatcar in this manual.
G.Start the engine and let it run slowly.
IMPORTANT: Keep the doors wide open and move the machine outside of the storage room immediately to avoid danger from exhaust fumes. Do not accelerate the engine rapidly or operate it at high speed immediately after starting.
NOTE: CUB CADET CORPORATION reserves the right to make improvements in design or changes in specifications at any time without incurring any obligation to install them on units previously sold.