28Cyclades PM IPDU Installer/Administrator/User Guide

Figure 3.1: Sending Firmware using HyperTerminal

2.Click the Browse button to set the proper path for the Cyclades PM IPDU firmware file located on your work station.

NOTE: You must browse for the proper file and click the Send button within 10 seconds of selecting Transfer-Send. If you fail to do so, an error message will appear and the transmission will fail. You will then be given another 10-second window in which to repeat steps 1. through 4.

3.Select Xmodem as the protocol.

4.Click on the Send button.

To use Minicom in Linux:

1.From the main screen, press Ctrl+A S (for sending files). The Upload pop-up window appears.

2.Select xmodem as the protocol.

The Select a file for upload window appears.

3.Move the cursor next to the Cyclades PM IPDU firmware file for upload, and press the Spacebar to tag it. See Figure 3.2.

4.Press Enter to start the file transfer.

Page 40
Image 40
Cyclades PM IPDU manual To use Minicom in Linux, Sending Firmware using HyperTerminal