Symbologies
UK-Plessey — continued
Code I.D. Selection
The Code I.D. for this symbology consists of one or two
Example: Setting the UK/Plessey Code I.D.
To configure this feature:
1.Determine which character(s) you would like to use to represent the UK/Plessey symbology. Reference Appendix A, ASCII Conversion Chart to find the corresponding hex values for your chosen charac- ter(s). In this example we’ll set a Code I.D. of “@” to represent UK/Plessey. The value from the table corresponding to ‘’@’ is 40. This value will be used in a step to follow.
2.Scan the START bar code
3.Scan the SET UK/PLESSEY CODE I.D. bar code.
4.Turn to Appendix B,
5.Scan the SET bar code to accept the digits scanned.
6.Turn to the Data Editing chapter and scan the CODE ID POSI- TION: BEFORE BAR CODE DATA label.
Features configured using the Data Editing chapter are universal and will affect all symbologies.
NOTE
7.Scan the END bar code to exit Programming Mode.
8.The resulting message string for scanned UK/Plessey labels would appear as follows:
Scanned bar code data: | 0123456789123 |
Resulting message string output: @0123456789123
QuickScan® QS6500/QS6500 BT |