Bluetooth Models
Unlinking
There are three ways to unlink an imager from a Base Station:
Unlink and Sleep
1.Scan the “Unlink and Sleep” bar code — Reading the unlink bar code above while the imager is in range of the Base Station will break the link between the two devices and allow another imager to link to the Base Station. It will also place the imager in Sleep Mode. If the bar code is read when the imager is out of range of its linked Base Station, the imager will unlink, but the Base Station will remain linked to the imager and will not allow another imager to be linked to it until the unlink button is pressed, the original imager is brought in range, linked, and then unlinked again.
2.Push the button on the bottom of the Base Station — Pushing the but- ton on the Base Station while the imager is in range will break the link between the devices. If the button is pushed while the imager is out of range, the Base Station will unlink and make itself avail- able to other imagers. The imager will not automatically break its link with the Base Station, but can be linked to any other Base Sta- tion by reading its link label .
3.Scan the link label on an alternate Base Station — Scanning the link label on a Base Station with an imager that is linked with another Base Station will drop the link between the original pair and estab- lish a link between the imager and the new Base Station. If the new link is performed within range of the old Base Station, it is free to establish a link to the next imager that reads its link label. If it is done outside the range of the old Base Station, it retains its old link and will not allow a new imager to link to it until its unlink button is pressed.
QuickScan® QS6500/QS6500BT |