Symbologies
RSS Expanded — continued
Code I.D. Selection
The Code I.D. for this symbology consists of one or two
Example: Setting the RSS Expanded Code I.D.
To configure this feature:
1.Determine which character(s) you would like to use to represent the RSS Expanded symbology. Reference Appendix A, ASCII Con- version Chart to find the corresponding hex values for your chosen character(s). In this example we’ll set a Code I.D. of “RX” to repre- sent RSS Expanded. The value from the table corresponding to ‘’R’ is 52 and the value for ‘X’ is 58. These values will be used in a step to follow.
2.Scan the START bar code
3.Scan the SET RSS Expanded CODE I.D. bar code.
4.Turn to Appendix B,
5.Scan the SET bar code to accept the digits scanned.
6.Turn to the Data Editing chapter and scan the CODE ID POSI- TION: BEFORE BAR CODE DATA label.
Features configured using the Data Editing chapter are universal and will affect all symbologies.
NOTE
7.Scan the END bar code to exit Programming Mode.
8.The resulting message string for scanned RSS Expanded labels would appear as follows:
Scanned bar code data: | 0123456789123 |
Resulting message string output: RX0123456789123
QuickScan® QS6500/QS6500 BT |