Symbologies
6-52 QuickScan® QS6500/QS6500 BT
RSS Expanded — continued
Code I.D. Selection
The Code I.D. for this symbology consists of one or two user-selectable
ASCII characters. It can be appended previous to or following the trans-
mitted RSS Expanded bar code data depending on how this feature is
enabled.
Example: Setting the RSS Expanded Code I.D.
To configure this feature:
1. Determine which character(s) you would like to use to represent
the RSS Expanded symbology. Reference AppendixA, ASCII Con-
version Char t to find the corresponding hex values for your chosen
character(s). In this example we’ll set a Code I.D. of “RX” to repre-
sent RSS Expanded. The value from the table corresponding to
‘’R’ is 52 and the value for ‘X’ is 58. These values will be used in a
step to follow.
2. Scan the START bar code
3. Scan the SET RSS Expanded CODE I.D. bar code.
4. Turn to AppendixB, Alpha-Numeric Pad and scan the bar codes ‘5’
and ‘2’ (the value determined in an earlier step to represent ‘R’).
Then scan the bar codes ‘5’ and ‘8’ (hex equivalent for ‘X’).
5. Scan the SET bar code to accept the digits scanned.
6. Turn to the Data Editing chapter and scan the CODE ID POSI-
TION: BEFORE BAR CODE DATA label.
7. Scan the END bar code to exit Programming Mode.
8. The resulting message string for scanned RSS Expanded labels
would appear as follows:
Scanned bar code data: 0123456789123
Resulting message string output: RX0123456789123
NOTE
Features configured using the Data Editing chapter are
universal and will affect all symbologies.