Symbologies

RSS Expanded — continued

Code I.D. Selection

The Code I.D. for this symbology consists of one or two user-selectable ASCII characters. It can be appended previous to or following the trans- mitted RSS Expanded bar code data depending on how this feature is enabled.

Example: Setting the RSS Expanded Code I.D.

To configure this feature:

1.Determine which character(s) you would like to use to represent the RSS Expanded symbology. Reference Appendix A, ASCII Con- version Chart to find the corresponding hex values for your chosen character(s). In this example we’ll set a Code I.D. of “RX” to repre- sent RSS Expanded. The value from the table corresponding to ‘’R’ is 52 and the value for ‘X’ is 58. These values will be used in a step to follow.

2.Scan the START bar code

3.Scan the SET RSS Expanded CODE I.D. bar code.

4.Turn to Appendix B, Alpha-Numeric Pad and scan the bar codes ‘5’ and ‘2’ (the value determined in an earlier step to represent ‘R’). Then scan the bar codes ‘5’ and ‘8’ (hex equivalent for ‘X’).

5.Scan the SET bar code to accept the digits scanned.

6.Turn to the Data Editing chapter and scan the CODE ID POSI- TION: BEFORE BAR CODE DATA label.

Features configured using the Data Editing chapter are universal and will affect all symbologies.

NOTE

7.Scan the END bar code to exit Programming Mode.

8.The resulting message string for scanned RSS Expanded labels would appear as follows:

Scanned bar code data:

0123456789123

Resulting message string output: RX0123456789123

6-52

QuickScan® QS6500/QS6500 BT

Page 140
Image 140
Datalogic Scanning QS6500BT manual Example Setting the RSS Expanded Code I.D