Section 1

Getting Started

DriveRack

 

 

 

 

1.1 Rear Panel Connections

IEC Power Cord Receptacle

The DriveRack 260 comes with a power supply that will accept voltages ranging from 100V- 120V at frequencies from 50Hz-60Hz. An IEC cord is included. EU version accepts 220V-240V at frequencies from 50Hz-60Hz.

Power Switch

The Power Switch turns the DriveRack 260 on and off. Note: dbx Professional Products rec- ommends that power amplifiers connected to the DriveRack 260, should be powered down prior to cycling the power on the DriveRack 260.

PC Connection

This DB-9 type connection is used to send and receive information to and from the GUI inter- face.

RS485 Zone Control Input (RJ-45 connector type)

This input connection is used to send information and power to the ZC wall controllers.

Outputs 1-6

The output section of the DriveRack 260 offers six electronically balanced XLR connectors.

Inputs 1-2

The input section of the DriveRack 260 offers two electronically balanced XLR connectors.

Ground Lift Switch

The ground lift switch lifts the pin 1 chassis ground of both input XLR connectors.

RTA Input Jack

This balanced XLR input is used for the connection of an RTA microphone, which allows the user to “Pink” and optimize the EQ settings of any room through the use of the Auto EQ in the Wizard setup assistant.

1.2 Front Panel

®

2

DriveRack™ User Manual

 

 

Page 10
Image 10
dbx Pro 260 user manual Getting Started, Rear Panel Connections, Front Panel