dbx Pro 260 Utility, LCD Contrast, Auto EQ Plot, Power Up Modes, PUP Program, Stored, PUP Mute

Models: 260

1 83
Download 83 pages 25.98 Kb
Page 48
Image 48
Utility

Section 5

Utilities/Meters

DriveRack

 

 

 

 

The Utility section of the 260 DriveRack gives you the ability to perform several key operational functions to the DriveRack including: Security settings, Power-up features, Program list organi- zation, Auto EQ plotting, adjustment of Output Jumper settings and Display contrast settings. Additionally, pressing and holding the utility button will allow you to enter the metering sec- tion of the 260. This section lets you monitor aspects of the unit including: Compression, Limiting, Zone Controller levels and Output trim. Use this section of the manual to make your- self familiar with all aspects of the Utility menu of the DriveRack system.

5.1.1 -Page 1 - LCD Contrast / Auto EQ Plot

Page 1 of the Utility menu offers LCD contrast control and Auto EQ Plot selection. Since venues and applications vary, the 260 DriveRack provide you with the option of changing the contrast of the custom display. To make any adjustments to the display contrast, press the UTILITY button and the page will appear as follows:

Utility

 

LCD Contrast

10

Auto EQ Plot

RTA

 

 

Select the Contrast adjustment by pressing the DATA wheel until the con- trast percentage is selected. Once the contrast has been selected, proceed to rotate the DATA wheel until the desired contrast has been established. Contrast adjust ranges from 01 to 16.

Select the RTA or GEQ for the Auto EQ plot press the DATA wheel until the Auto EQ Plot is selected. Once the desired option has been selected, pro- ceed to rotate the DATA wheel select either RTA or GEQ. To exit, press the PROGRAM/CONFIG button.

5.1.2-Page 2 - PUP Program/Mute

The Utility menu of the 260 DriveRack also offers the option of setting the PUP (Power Up) Program option of either Current or Stored and PUP Mutes, which allows to you power up with all outputs either muted or at the last setting prior to powering down. The following explains the difference between Load On and Load OFF settings. To access and edit the Load Stored option of the unit, use the following procedure.

From Program mode, press the UTILITY button and use the PREV PG and NEXT PG but- ton to move to the page that appears as follows:

Power Up Modes

 

PUP Program

Stored

PUP Mute

Current

 

 

Stored: After cycling the power (or power failure), the unit will automatically load a program from the program table. No unstored edits will be saved.

®