Indicators, Messages, and Codes 19
Error: RAC cannot be used
with an add-in video card
in this slot.
Add-in video card is installed. Remove the add-in video card. See
"Installing and Removing a CERC SATA
RAID Controller" in "Installing System
Components." To use the add-in video
card, remove the RAC.
Gate A20 failure Faulty keyboard controller (faulty
system board).
See "
Getting Help
."
General failure Operating system corrupted or
improperly installed.
Reinstall the operating system.
Hard disk controller
failure
Incorrect configuration settings in
System Setup program.
Run the System Setup program to
correct the settings. See "Using the
System Setup Program" in your User's
Guide.
Faulty or improperly installed hard
drive, or loose power cable.
Ensure that the hard-drive subsystem is
properly installed. See "Troubleshooting
Hard Drives" in "Troubleshooting Your
System" for the type of hard drive
installed in your system.
Invalid memory
configuration detected.
Potential corruption
exists!
Memory module installation
guidelines have not been properly
followed.
Ensure that the memory modules are
properly populated. See "Memory
Module Installation Guidelines" in
"Installing System Components."
Keyboard controller
failure
Faulty keyboard controller (faulty
system board).
See "Getting Help."
Keyboard data line failure
Keyboard failure
Keyboard stuck key failure
Loose or improperly connected
keyboard cable; faulty keyboard; faulty
keyboard controller.
Ensure that the keyboard is properly
connected. If the problem persists,
replace the keyboard. If the problem
persists, see "Troubleshooting the
System Board" in "Troubleshooting Your
System."
Table 2-3. System Messages (continued)
Message Causes Corrective Actions