w w w . d e l l . c o m s u p p o r t . d e l l . c o m

Table 2-3. System Messages (continued)

Message

Causes

Corrective Actions

 

 

 

Memory address line

Faulty or improperly installed memory

Ensure that all memory modules are

failure at address, read

modules, or faulty system board.

properly installed. See "Troubleshooting

value expecting value

 

System Memory" in "Troubleshooting

Memory double word logic

 

Your System." If the problem persists, see

 

"Troubleshooting the System Board."

failure at address, read

 

 

 

value expecting value

 

 

Memory odd/even logic

 

 

failure at start address

 

 

to end address

 

 

Memory write/read failure

 

 

at address, read value

 

 

expecting value

 

 

 

 

 

Memory allocation error

Faulty application program.

Restart the application program.

 

 

 

Memory bank population

Memory modules are not installed in

Ensure that the memory modules are

error!

identical pairs; faulty memory

properly installed. See "Memory Module

 

module(s).

Installation Guidelines" in "Installing

 

 

System Components." If the problem

 

 

persists, see "Troubleshooting System

 

 

Memory" in "Troubleshooting Your

 

 

System."

 

 

 

Memory parity interrupt at

Faulty or improperly installed memory

Ensure that all memory modules are

address

modules.

properly installed. See "Memory Module

 

 

Installation Guidelines" in "Installing

 

 

System Components." If the problem

 

 

persists, see "Troubleshooting System

 

 

Memory" in "Troubleshooting Your

 

 

System."

 

 

 

Memory tests terminated by

The spacebar was pressed during

Information only.

keystroke

POST to terminate the memory test.

 

20

Indicators, Messages, and Codes

Page 20
Image 20