Table 2-4. Server Module Beep Codes (continued)

Code

Cause

Corrective Action

 

 

 

3-1-1

Slave DMA-register failure

Faulty system board. See "Troubleshooting the

3-1-2

Master DMA-register failure

System Board" in "Troubleshooting Your System."

 

3-1-3

Master interrupt-mask register

 

 

failure

 

3-1-4

Slave interrupt-mask register failure

 

3-2-2

Interrupt vector loading failure

 

3-2-4

Keyboard-controller test failure

 

3-3-1

CMOS failure

 

3-3-2

System configuration check failure

 

3-3-3

Keyboard controller not detected

 

3-3-4

Video memory test failure

 

3-4-1

Screen initialization failure

 

3-4-2

Screen-retrace test failure

 

3-4-3

Video ROM search failure

 

4-2-1

No timer tick

 

4-2-2

Shutdown test failure

 

4-2-3

Gate A20 failure

 

 

 

 

4-2-4

Unexpected interrupt in protected

See "Troubleshooting Expansion Cards" in

 

mode

"Troubleshooting Your System."

 

 

 

4-3-1

Improperly installed or faulty

See "Troubleshooting System Memory" in

 

memory modules

"Troubleshooting Your System."

4-3-2 No memory modules installed in the first memory module connector

Install a memory module in the first memory module connector. See "Installing Memory Modules" and "Memory Module Installation Guidelines" in "Installing System Components."

4-3-3

Faulty system board

Faulty system board. See "Troubleshooting the

 

 

System Board" in "Troubleshooting Your System."

 

 

 

4-3-4

Time-of-day clock stopped

See "Troubleshooting System Memory" in

 

 

"Troubleshooting Your System." If the problem

persists, see "Troubleshooting the System Board" in "Troubleshooting Your System."