Chapter 3 Creating and Editing Screens
3-184 Revision May, 2010
Property Description of Historical Event Table Elements
Buffer ID
Use this option to set the number (No.1 ~ No.X) of
history buffer for reading the data of PLC
corresponding address. The user can press the
History Buffer Setup button or click Option > History
Setup (Choosing History Setup command from menu
bar) to set the PLC corresponding address.
Data No.
It is used to set the reading Word data when triggering
every time. For example, if the Data Length option in
the History Setup dialog box is set to 3words, there are
0 ~ 2 data numbers can be selected in this option.
Time/Date
Time Format
Provide HH:MM:SS, HH:MM two kinds of formats.
Date Format
Provide MM/DD/YY, DD/MM/YY, DD.MM.YY,
YY.MM.DD, YY/MM/DD, MM.DD, MM/DD seven kinds
of formats.
Setting
Color When time or date format is selected, the user can use
this option to designate the display color.
X Used to set X coordinate
Y Used to set Y coordinate
Width Used to set the element width
Height Used to set the element height