Chapter 3 Creating and Editing Screens
Revision May, 2010 3-215
Function Description
Cycle Macro Delay Time
Sets Macro Cycle Delay time every time this screen is executed.
The range of the macro cycle delay time is between 100ms to
5s.
Fast Refresh Rate
There are three levels of the Fast Refresh Rate and they are
High, Medium and Low. The purpose of this function is used to
make some elements be displayed immediately when switching
screens.
Please note that this function is designed to provide fast
value refresh speed for the element which performs
communication frequently. Therefore, it only allows four
elements that can be renewed immediately in each screen. If
the user uses this function on too many elements, it may
affect the normal speed of HMI operation. So, we
recommend the user not to activate this function if not
necessary.
Setting
The user can find this function only in DOP-B series HMI which
supports printer function. If the user wants to enable this
function, setting the printer in advance is necessary. Please go
to Option > Configuration > Printer Setup and select the
printer first. When this function is enabled, if one report list
button is created and its assigned output device is a printer,
once the user presses the report list button, HMI will refer to
the setting in Hard Copy Region option and execute the
screen-printing.
Top-Left
Hard Copy
Region
Right-Bottom
Set the region of HMI printing area (also called Hard Copy
Region) and the unit is Pixel.
Need Base
Screen Setting
Every screen can specify any one of the editing screens as a
base screen. When the check box next to Need Base Screen
is
checked, the base screen will be moved to the back (behind all
other elements) as a ground picture. After compile operation is
completed and the screen data is downloaded to HMI, HMI will
execute all of the elements on the base screen correctly.