Reference Manual
Rosemount 3051N
Message |
| Description |
|
|
|
ROM checksum |
| Checksum of transmitter software has detected a fault. Return |
error ON |
| to Rosemount Nuclear Instruments, Inc. for repair. |
|
|
|
Save data from |
| Prompts user to press SAVE softkey to initiate a |
device to |
| |
configuration |
|
|
memory |
|
|
|
|
|
Saving data to |
| Data is being transferred from a device to configuration |
configuration |
| memory. |
memory. |
|
|
|
|
|
Sending data to |
| Data is being transferred from configuration memory to a |
device. |
| device. |
|
|
|
Sensor board not |
| The sensor module electronics board is not initialized. Return |
initialized ON |
| to Rosemount Nuclear Instruments, Inc. for repair. |
|
|
|
There are write only |
| There are |
variables which |
| user. These variables should be set or invalid values may be |
have not been |
| sent to the device. |
edited. Please edit |
|
|
them. |
|
|
|
|
|
There is unsent data. |
| Press YES to send unsent data and turn the HC off. Press NO |
Send it before |
| to turn the HC off and lose the unsent data. |
shutting off? |
|
|
|
|
|
Too few data bytes |
| Command returns fewer data bytes than expected as |
received |
| determined by the device description. |
|
|
|
Transmitter Fault |
| Device returns a command response indicating a fault with the |
|
| connected device. |
|
|
|
Units for <variable |
| The engineering units for this variable have been edited. Send |
label> has changed. |
| engineering units to the device before editing this variable. |
Unit must be sent |
|
|
before editing, or |
|
|
invalid data will be |
|
|
sent. |
|
|
|
|
|
Unsent data to |
| There is unsent data for a previously connected device which |
online device. SEND |
| must be sent or thrown away before connecting to another |
or LOSE data |
| device. |
|
|
|
Upgrade 275 |
| The communicator does not contain the most recent |
software to access |
| Rosemount 3051N Device Descriptors (DDs). Select YES to |
XMTR function. |
| communicate using the existing DDs. Select NO to abort |
Continue with old |
| communication. |
description? |
|
|
|
|
|
Use up/down arrows |
| Gives direction to change the contrast of the HC display. |
to change contrast. |
|
|
Press DONE when |
|
|
done. |
|
|
|
|
|