Enterasys Networks X-PeditionTM manual Configuring Interface as the Backup Dialer Interface

Models: X-PeditionTM

1 466
Download 466 pages 52.77 Kb
Page 237
Image 237

Configuring a Dialed Backup Line

Configuring the Physical Interface for the Dialer Interface

Perform the following steps to set up the physical port for the dialer interface:

1.Enter interface serial card / port to specify the interface.

2.Enter encapsulation ppp to set PPP encapsulation.

3.Enter dialer pool-memberpool-numberpriority priority to assign the interface as a member of the pool that the dialer interface will use.

Priority is an optional value you can configure to prioritize this pool-member within the pool.

Configuring Interface as the Backup Dialer Interface

Perform the following steps to configure the port for the dialer backup interface:

1.Enter interface serial card/port to specify the interface to back up.

2.Enter ip address ip-address mask to specify the IP address and mask of the interface.

3.Enter backup interface dialer number as the backup interface.

4.Enter backup delay enable-delaydisable-delayto set the interval between the physical interface going down and the backup being enabled, and between the physical interface coming back up and the backup being disabled.

5.Enter backup time-rangestart-timeend-timeto set the time of day the backup interface should be enabled and disabled.

The CLI commands shown below are those used to configure the example shown in Figure 10-7on page 10-14.

Create interface dialer 1 to use dialer pool 6:

XSR(config)#interface dialer1

XSR(config-if<D1>)#encapsulation ppp

XSR(config-if<D1>)#dialer pool 6

XSR(config-if<D1>)#no shutdown

Configure backup serial port for dialing purposes:

XSR(config)#interface serial 1/0

XSR(config-if<S1/0)#dialer pool-member 6

XSR(config-if<S1/0)#no shutdown

Configure primary serial port to have interface dialer1 as its backup interface:

XSR(config)#interface serial 1/1

XSR(config-if<S1/1)#backup interface dialer1

XSR(config-if<S1/1)#backup delay 5 10

XSR(config-if<S1/1)#backup time-range 10:00 22:55

XSR(config-if<S1/1)#no shutdown

The backup time-rangecommand specifies the time the backup dial line should be up. In the above example the parameters are 10:00 and 22:55, meaning that at 10:00 the backup line should be activated and at 22:55 the backup line should be deactivated. Enabling and disabling the backup interface takes place regardless of the traffic on the link when using the backup time- range command.

XSR User’s Guide 10-15

Page 237
Image 237
Enterasys Networks X-PeditionTM manual Configuring Interface as the Backup Dialer Interface