System Alarms and Events

Table A-7 Medium Severity Alarms/Events (continued)

Module

Message

Description

 

 

 

PPP

PPP MS-CHAP authentication failed while

PPP MS-CHAP authentication has failed while being authenticated by

 

being authenticated by remote peer

the remote peer.

 

 

 

PPP

PPP MS-CHAP authentication success

PPP MS-CHAP authentication has passed while authenticating the

 

while authenticating remote peer's

remote peer's response.

 

response

 

 

 

 

PPP

PPP MS-CHAP authentication success

PPP MS-CHAP authentication has passed while being authenticated

 

while being authenticated by remote peer

by the remote peer.

 

 

 

PPP

PPP PAP authentication failed while

PPP PAP authentication has failed while authenticating the remote

 

authenticating remote peer

peer.

 

 

 

PPP

PPP PAP authentication failed while being

PPP PAP authentication has failed while being authenticated by the

 

authenticated by remote peer

remote peer.

 

 

 

PPP

PPP PAP authentication success while

PPP PAP authentication has passed while authenticating a remote

 

authenticating remote peer

peer.

 

 

 

PPP

PPP PAP authentication success while

PPP PAP authentication has passed while being authenticated by a

 

being authenticated by remote peer

remote peer.

 

 

 

PPP

Line protocol on Interface <interface

A line protocol on an interface comes up.

 

name>, changed state to up

 

PPPLine protocol on Interface <interface name>, changed state to down

A line protocol on an interface goes down.

PLATF

Failed to set syslog rx buf to zero

Cannot set recv buffer to zero to discard received syslogs.

 

 

 

ISDN

Incoming Call <BRI Serial card/

The incoming call is connected to the shown channel.

 

port:channel> Connected to <calling no.>

 

 

<destination name>

 

 

 

 

ISDN

Call <BRI Serial card/port:channel>

Test call disconnected due to standard ISDN cause. E.g. 16: normal

 

Connected to <called_no> <destination

clearing, 18: user does not answer.

 

name>

 

ISDN

Call <BRI Serial card/port:channel>

 

Disconnected from <number>

 

<destination name> Cause <passed from

 

CO>

The call is disconnected, due to the standard ISDN cause. E.g. 16 normal clearing, 18 User does not answer.

FR

Serial a/b:d Config Good Aggregate CIR

 

nnn less than measured speed+D137

 

nnnn - CIR Assist is ENABLED

Total configured CIR is within 125% of the port measured speed - CIR assisting is enabled.

ETH0_

PHY read operation time-out

The PHY chip on the FastEthernet 1 port has had an error (other than

DRIV

 

time-out) while processing a read request. Port functionality may or

 

 

may not be affected: the port is still available, but its functionality may

 

 

be diminished. The cause of this alarm is most likely HW failure.

 

 

 

ETH0_

PHY read operation unsuccessful

The PHY chip on the FastEthernet 1 port has had an error (other than

DRIV

 

time-out) while processing a read request. Port functionality may or

 

 

may not be affected: the port is still available, but its functionality may

 

 

be diminished. The cause of this alarm is most likely HW failure.

 

 

 

ETH0_

PHY write operation time-out

The PHY chip on the FastEthernet 1 interface has timed-out while

DRIV

 

processing a write request. When this occurs, port functionality may or

 

 

may not be affected. The port will still be available, but its functionality

 

 

may be diminished. The cause of this alarm is most likely HW failure.

A-10 Alarms/Events, System Limits, and Standard ASCII Table

Page 432
Image 432
Enterasys Networks X-PeditionTM manual PPP MS-CHAP authentication failed while