System Alarms and Events

 

 

Table A-8 Low Severity Alarms/Events (continued)

 

 

 

 

Module

Message

Description

 

 

 

SYNC_

Packets lost > 255 (RX overrun)

Sum of packets lost due to RX FIFO overrun exceeded 255.

DRIV

 

 

PPOut of memory - frame dropped at port <port number>

Frame is dropped at the specified port from depleted memory.

PLATF

Need 'snmp-server system-shutdown' for SNMP

SNMP configuration does not allow reboots.

 

reboot

 

 

 

 

FR

Serial a/b:d.e, packet arrived on unconfigured

Data is discarded

 

DLCI nnnn

 

 

 

 

ETH1_

Recoverable error

FastEthernet 2 chip (of the interface) has experienced a

DRIV

 

significant but recoverable problem. The interface has already

 

 

corrected the problem by resetting itself.

 

 

 

ETH1_

Packets lost > 255 (RX overrun)

Sum of packets this interface has lost (discarded) due to RX

DRIV

 

FIFO overrun exceeds 255. This alarm will occur only once.

 

 

 

ETH0_

Recoverable error

FastEthernet 1 chip (of the interface) has experienced a

DRIV

 

significant, but recoverable problem. The interface has already

 

 

corrected the problem by resetting itself.

 

 

 

ETH0_

Packets lost > 255 (RX overrun)

Sum of packets this interface has lost (discarded) due to RX

DRIV

 

FIFO overrun exceeding 255. This alarm will occur once only.

 

 

 

CLI

Login failed from address <IP address> due

Timeout error during login.

 

to timeout

 

 

 

 

ASYNC_

Recoverable error

The device has hard recoverable error.

IDRIV

 

 

 

 

 

ASYNC_

Packets lost > 255 (RX overrun)

Sum of packets lost due to RX FIFO overrun exceeded 255.

IDRIV

 

 

FR

Serial a/b:d unconfigured DLCI nn reported

 

active by LMI

UNI-DCE has announced a DLCI as active but is not yet configured on the XSR. The DLCI should be configured, if required.

FR

Serial a/b:d Fragmentation not configured for

 

DLCI nn - FRF.12 Packet received.

The remote side of the connection is sending FRF.12 packets, but the XSR is not configured locally to transmit FRF.12 packets. Any voice traffic may experience unnecessary delays.

FR

Serial a/b:d clock lost - speed detected nn bps

Frame Relay has detected a clock that is too slow and is

 

 

bringing the interface operationally down until the clock

 

 

reappears. If this problem persists, you may want to check the

 

 

attached equipment or contact the service provider.

FR

Serial a/b:d clock recovered - speed detected nn

 

bps

Frame Relay has detected a proper clock and is bringing the interface operationally up. LMI should re-establish shortly thereafter and DLCIS will start to pass traffic.

SERIAL Serial a/b - DSR Down CTS Up (MUX_DOWN) Serial port has detected an EIA transition which will cause an interface down condition. This alarm is additional to the high severity Interface <interface name>, changed state to down}

SERIAL Serial a/b - DSR/CTS Down (MUX_DOWN)

Serial port has detected an EIA transition which will cause an interface down condition. This alarm is additional to the high severity Interface <interface name>, changed state to down}

XSR User’s Guide A-13

Page 435
Image 435