Epson TM-FX2180 manual Removing the HP Sensor, Removing the PW Sensor Assembly

Models: TM-FX2180

1 103
Download 103 pages 6.27 Kb
Page 53
Image 53

EPSON FX-2180 Service Manual

Chapter 4 Disassembly and Assembly

 

 

4.2.4Removing the HP Sensor

1.Remove the printer cover, ribbon cartridge, front edge guide, and front cover. (See section 4.2.1.)

2.Disconnect the connector cable for the HP sensor.

IMPORTANT

 

 

 

Note the orientation of the HP sensor so you can

 

 

reinstall it the same way. See Figure 4-8.

 

 

 

 

 

 

3.Remove the HP sensor from the front paper entrance by pushing up and releasing the two clips at the bottom of the HP sensor.

2 clips securing the HP sensor

Figure 4-8. Removing the HP Sensor

4.2.5Removing the PW Sensor Assembly

1.Remove the printer cover and ribbon cartridge. (See section 4.2.1.)

2.Remove the print head. (See section 4.2.3.)

3.Remove the CB screw (2.5 × 5) securing the PW sensor to the ribbon mask holder.

4.Release the three clips on the CR cover that secure it to the bottom of the CR assembly. Then lift the cover slightly.

5.Remove the FFC from the PW sensor connector on the CR cover.

6.Remove the PW sensor assembly along with the CR cover by pushing and releasing the clip for the CR cover, as shown in Figure 4-9.

P W s e n

P W s e n s o r a s s e m b ly

C R c o

C R

a s s e m b

C B s c r e w ( 2 . 5

x 5 )

Figure 4-9. Removing the PW Sensor Assembly

4-8

Page 53
Image 53
Epson TM-FX2180 manual Removing the HP Sensor, Removing the PW Sensor Assembly