EPHD04+ HDcctv DVR
6.4.2.2 HD Temperature
Figure
Log: Check the box to record alarm events to log data.
Buzzer: Check the box to enable buzzer when Hard Disk’s (HD) temperature is over the “Temp. Warning Limit”.
Email Notify: Check the box to send email notification when Hard Disk’s (HD) temperature is over the “Temp. Warning Limit”. Email operation requires valid email entered in the Email setup menu (see 6.6.2 Email).
Network Alarm: Check the box to send out a network alarm to a client PC. This feature works with EverFocus’ CMS software, including PowerCom and PowerVideo Plus. You will need to configure the Alarm Server for the DVR to send network alarms to the client PC (see 6.6.4 Alarm Server).
Stop Recording: Check box to stop recording when HD’s temperature is over the “Temp. Warning Limit”.
Temp. Warning Limit: Sets the trigger temperature for HD Temperature event actions. Choose between 50°C /122°F and 70°C /158°F.
Alarm Output: Select an alarm output number. When an alarm is triggered, the signal will be transmitted through the selected alarm output relay.
Output Type: Output action will be Transparent and cannot be changed (alarm output remains as long as the alarm condition is active).
70