Extron electronic AVT 200HD manual Symbol Definitions for IP-specific Commands, X4#, X5# X5$

Models: AVT 200HD

1 118
Download 118 pages 5.05 Kb
Page 62
Image 62

Symbol Definitions for IP-specific Commands

X4!

=

Port number

0199(represented as two ASCII characters with

 

 

 

leading zero if required

X4@

=

Command data section

Factory default name (model name + last 3 pairs of

 

 

 

MAC address)

X4#

=

GMT offset

–12.0through +14.0. Represents hours and minutes

 

 

 

offset from Greenwich mean time (GMT).

X4%

=

On and off status

0

= off or disabled

 

 

 

1

= on or enabled

X4^

=

Dirty RAM status

0

= Random access memory has been saved to flash

 

 

 

1

memory (OK to power off or reset).

 

 

 

= RAM needs to be saved to flash memory

X5!

=

Firmware version number

n.nn (listed to two decimal places)

X5@

=

Unit name

Up to 24 characters: alphabetical (AZor az), digits

 

 

 

(09), or hyphen (-).

NOTES: The following characters are invalid or not recommended in names:

 

{space} + ~ , @ = ` [ ] { } < > ‘ ’

“ ” ; : \ and ?.

The first character must be alphabetical.

 

The last character must not be a hyphen.

 

X5#

X5$

X5^

X5&

X5*

X5(

=

Local date and time format

For setting:

 

 

In the format MM/DD/YY•HH:MM:SS

 

 

MM = month: 10 (January) through 12 (December)

 

 

DD = 01 through 31

 

 

YY = 00 through 99

 

 

HH = 00 through 23

 

 

MM = 00 through 59

 

 

SS = 00 through 59

 

 

For reading:

 

 

In the format Day,•DD•Mmm•YYYY•HH:MM:SS:

 

 

Day = weekday: Mon through Sun

 

 

DD = 01 through 31

 

 

Mmm = month: (Jan through Dec)

 

 

YYYY = year: 2000 through 2099

 

 

HH = 00 through 23

 

 

MM = 00 through 59

 

 

SS = 00 through 59

=

IP address

nnn.nnn.nnn.nnn

 

 

(Leading zeros in each of the four fields are optional

 

 

for setting values and are suppressed in returned

 

 

values.

 

 

Factory default address: 192.168.254.254

 

 

Default broadcast IP address: 255.255.255.255

= Power-up delay between ports in

1 through 255.

 

1/3 second increments.

Default = 3, or 1 second.

= Time (in 10-ms increments) to wait

10 through 32767

 

for characters to come into a serial

Default = 10, or 100 ms

 

port before terminating the

 

 

connection

 

= Time (in 10-ms increments) to wait

2 through 32767

 

between characters before

Default = 2, or 20 ms

 

terminating the connection

 

=

Hardware (MAC) address

00-05-A6-xx-xx-xx