Extron electronic AVT 200HD manual X6#, X6$, X7#, X7$

Models: AVT 200HD

1 118
Download 118 pages 5.05 Kb
Page 63
Image 63

X6) = Subnet mask

X6! = Message length, delimiter value, or byte count (via the serial port). (This parameter is optional.)

X6@ = Verbose mode

nnn.nnn.nnn.nnn

(Leading zeros in each of the four fields are optional for setting values and are suppressed in returned values.

Default = 255.255.0.0

nL = Length of message to be received nD = Delimiter value

n = byte count (1 through 32767; default is 0) Placed in front of the parameter (nD or nL)

0 = clear or none (default for Telnet connection)

1 = verbose mode (default for RS-232 connection)

2 = tagged responses for queries

3 = verbose mode and tagged responses for queries

NOTE:

If tagged responses is enabled (modes 2 and 3), all read commands return the constant

 

 

string and the value as the set command does (for example, the read name command

 

 

ECN} returns IpnX5@]).

 

X6#

=

Priority status for receiving timeouts 1 = use Send data string parameters (if they

 

 

 

exist) (default).

 

 

 

2 = use Configure receive timeout command

 

 

 

parameters instead.

X6$

=

IP address converted into a single

 

 

 

32-bit number

 

 

 

Example: 10.13.0.254 becomes (10*256*256*256) + (13*256*256) +

 

 

0*2456) + 254, which becomes (167,772,160 + 851,9678 + 254, which equals

 

 

68,624,382.

 

X6%

=

Baud rate

9600 (default), 19200, 38400, 115200

X6^

=

Parity

Odd, Even, None (default), Mark, Space (Only the

 

 

 

first letter is required.)

X6&

=

Data bits

7, 8 (default)

X6*

=

Stop bits

1 (default), 2

X6(

=

Port type

0 = RS-232 (default)

X7)

=

Flow control

Hardware, Software, None (default) (Only the first

 

 

 

letter is required.)

X7!

=

Data pacing

Specified in milliseconds between bytes:

 

 

 

0000 through 1000 (default = 0 ms)

X7@

=

Password

12 characters maximum

NOTE:

The following characters are invalid in passwords:

 

{space} + ~ , @ = ` [ ] { } < > ‘ ’

“ ” ; : \ and ?.

X7#

=

Daylight saving time

0 = off or ignore

 

 

 

1 = USA (Begins second Sunday in March and ends first

 

 

 

2

Sunday in November.)

 

 

 

= Europe (Begins last Sunday in March and ends last

 

 

 

3

Sunday in October.)

 

 

 

= Brazil (Begins third Sunday in October and ends

 

 

 

 

third Sunday in February.)

X7$

=

Event number

0 through 99 (event must be running)

X7%

=

Event buffer

0 = receive

 

 

 

1

= unified

 

 

 

2

= data

 

 

 

3

= NVRAM

X7^

=

Event buffer offset

0 through maximum buffer size

AVT 200HD Tuner • Remote Configuration and Control

57

Page 63
Image 63