Extron electronic MAV Plus Series, Ultra Series Operation, cont’d, Reset Mode Comparison/Summary

Models: Ultra Series MAV Plus Series

1 214
Download 214 pages 8.93 Kb
Page 100
Image 100
Reset Mode Comparison/Summary

Operation, cont’d

Reset Mode Comparison/Summary

Mode

Activation

 

Result

Purpose/Notes

 

 

 

 

1

Hold down the recessed Reset button

The switcher reverts to the factory default

Use mode 1 to revert

 

while applying power to the switcher.

firmware. Event scripting will not start if the

to the factory default

 

N After a mode 1 reset is

switcher is powered on in this mode. All user files

firmware version if

 

and settings (drivers, adjustments, IP settings, etc)

incompatibility issues

 

performed, update the

 

are maintained.

arise with user-loaded

 

switcher’s firmware to the

 

N If you do not want to update firmware, or

firmware.

 

latest version. Do not operate

 

 

 

the switcher firmware version

 

you performed a mode 1 reset by mistake,

 

 

that results from the mode

 

cycle power to the switcher to return to the

 

 

1 reset. If you want to use

 

firmware version that was running before

 

 

the factory default firmware,

 

the mode 1 reset. Use the 0Q SIS command

 

 

you must upload that version

 

to confirm that the factory default firmware

 

 

again. See chapter 5, “Matrix

 

is no longer running (look for the asterisk

 

 

Software”, for details on

 

[*] following the version number.

 

 

uploading firmware.

 

 

 

 

 

 

 

3

Hold down the Reset button for about

Mode 3 turns events on or off. During resetting,

Mode 3 is useful for

 

3 seconds, until the Reset LED blinks

the Reset LED flashes 2 times if events are starting,

troubleshooting.

 

once, then press Reset momentarily

3 times if events are stopping.

 

 

(<1 second) within 1 second.

 

 

 

 

 

 

 

4

Hold down the Reset button for

Mode 4:

Mode 4 enables you

 

about 6 seconds, until the Reset LED

Enables ARP capability.

to set IP address

 

blinks twice (once at 3 seconds and

• Sets the IP address to the factory default.

information using ARP

 

again at 6 seconds). Then press Reset

• Sets the subnet address to the factory default.

and the MAC address.

 

momentarily (<1 second) within 1

• Sets the gateway address to the factory default.

 

 

second.

• Sets port mapping to the factory default.

 

 

 

Turns DHCP off.

 

 

 

Turn events off.

 

 

 

The Reset LED flashes four times in quick

 

 

 

succession during the reset.

 

 

 

 

 

5

Hold down the Reset button for

Mode 5 performs a complete reset to factory

Mode 5 is useful if

 

about 9 seconds, until the Reset LED

defaults (with the exception of the firmware):

you want to start over

 

blinks three times (once at 3 seconds,

• Does everything mode 4 does.

with configuration and

 

again at 6 seconds, and then again

• Resets almost all real time adjustments:

uploading and also to

 

at 9 seconds). Then press Reset

 

clears all ties and presets, clears all audio or

replace events.

 

momentarily (<1 second) within 1

 

RS-232 mutes, clears all I/O grouping, clears

 

 

second.

 

all RGB delay settings to zero, and clears all

 

 

 

 

input and output audio settings.

 

N Mode 5 reset clears most

• Resets all IP options.

adjustments. To save these

• Removes/clears all files for the switcher.

settings, use the Windows-

The reset LED flashes four times in quick

based Matrix Switchers

succession during the reset.

Control Program and the

 

File > Save MATRIX

 

settings as... selection before

 

you perform this reset (See

 

chapter 5, “Matrix Software”).

 

For different reset levels, press and hold the button while the switcher is running or press and hold the button while you apply power to the switcher.

3-56 CrossPoint / MAV Matrix Switchers • Operation

Page 100
Image 100
Extron electronic MAV Plus Series, Ultra Series manual Operation, cont’d, Reset Mode Comparison/Summary, File Save MATRIX