Extron electronic MAV Plus Series manual Command/Response Table for IP-specific SIS Commands

Models: Ultra Series MAV Plus Series

1 214
Download 214 pages 8.93 Kb
Page 132
Image 132
Command/Response Table for IP-specific SIS Commands

Programmer’s Guide, cont’d

Command/Response Table for IP-specific SIS Commands

Symbol definitions

X3) = Matrix name

(Up to 240 alphanumeric characters)

NThe following characters are invalid in the name: {space} ~ , @ = ` [ ] { } < > ‘ “ ; : \ and ?.

X3! =

Default name

Factory default name (model name + last 3 pairs of MAC address)

X3@ =

Time and date (for set)

In the format MM/DD/YY•HH:MM:SS, where:

 

 

MM = month: 01 (January) through 12 (December)

 

 

DD = 01 through 31

 

 

YY = 00 through 99

 

 

HH = 00 through 23

 

 

MM = 00 through 59

 

 

SS = 00 through 59

X3# =

Time and date (for read)

In the format Day,•DD•Mmm•YYYY•HH:MM:SS, where:

 

 

Day = weekday: Mon through Sun

 

 

DD = 01 through 31

 

 

Mmm = month: Jan through Dec

 

 

YYYY = 2000 through 2099

 

 

HH = 00 through 23

 

 

MM = 00 through 59

 

 

SS = 00 through 59

X3$ =

GMT offset

–12.0 through +14.0. Hours and minutes removed from GMT

X3% =

Daylight Saving Time

0 = Daylight Saving Time off/ignore

 

 

1 = Daylight Saving Time on (northern hemisphere)

 

 

2 = Daylight Saving Time on (Europe)

 

 

3 = Daylight Saving Time on (Brazil)

X3^ =

IP address

###.###.###.###

X3& =

Hardware (MAC) address

##-##-##-##-##-##

X3* =

Number of open connections

0 - 255

X3( =

Password

12 alphanumeric characters

NThe following characters are invalid in passwords: {space} + ~ , @ = ` [ ] { } < > ‘ “ ; : \ and ?.

X4) = Domain name

Standard domain name rules apply (for example: nnnnn@xxx.com)

NThe following characters are invalid in a domain name: {space} + ~ , = ` [ ] { } < > ‘ “ ; : \ and ?. The @ character is acceptable only as the lead-in to the domain name (such as @extron.com).

X4! =

E-mail account

65 - 72. 65 = e-mail recipient 1, 66 = 2, 67 = 3, ... 72 = recipient #8

X4@

=

E-mail address

Typical e-mail address format (for example: nnnn@xxx.com)

X4#

=

Notify when?

0

= no response

3

= both 1 & 2

 

 

 

1

= fail/missing

4

= suspend

 

 

 

2

= fixed/restored

 

 

X4$ =

Notification selections

X4%

=

Notify status (for read)

X4^ = DHCP

X4& =

Port #

X4*

=

Baud rate

X4( =

Parity

X5)

=

Data bits

X5! =

Stop bits

X5@ =

Port type

Matrix size 2412 and larger:

01 - 32

= input 1 through input 32

 

98

= power supplies

 

99

= fans

Matrix size 1616 and smaller

01

- 17

= input 1 through input 16

 

17

= power supply

34- or 17-digit number. For each digit: 0 = do not notify, 1 = notify 0 =1 off, 1 = on

00 through 99 (00 = all ports) 9600, 19200, 38400, 115200

odd, even, none, mark, space (only the first letter required)

7, 8 1, 2

0 = RS-232

1 = RS-422

2 = RS-485

4-22 CrossPoint / MAV Matrix Switchers • Programmer’s Guide