Front Panel Operations

Front Panel Operations

The following paragraphs detail the power-up process and then provide sample procedures for the following actions:

Creating ties, sets of ties, and configurations

Changing a configuration

Viewing ties, sets of ties, and configurations

Assigning inputs and outputs to an I/O group

Setting the RGB delay

Saving a preset

Recalling a preset

Muting and unmuting outputs

Viewing and adjusting the input audio level

Viewing and adjusting the output volume

Locking the front panel

Performing front panel resets

Setting background illumination

Reading and setting the RS-232/RS-422 Remote port settings

Definitions

The following terms, which apply to all Extron matrix switchers, are used throughout this manual:

Tie — An input-to-output connection.

Set of ties — An input tied to two or more outputs. (An output can never be tied to more than one input.)

Configuration — One or more ties or one or more sets of ties.

Current configuration — The configuration that is currently active in the switcher (also called configuration 0)

Global memory preset — A configuration that has been stored. Up to 32 global memory presets can be stored in memory. Preset locations are assigned to the input buttons and (where necessary) output buttons. When a preset is retrieved from memory, it becomes the current configuration.

All models have 32 presets; on models with fewer than 32 input and output buttons, preset numbers that are too high to be available from the front panel are still accessible under serial port or Ethernet control.

Room — A subset of outputs that are logically related to each other, as determined by the operator. The switchers support up to 10 rooms, each of which can consist of from 1 to 16 outputs.

Room memory preset — A configuration consisting of outputs in a single room that has been stored. When a room preset is retrieved from memory, it becomes the current configuration.

CrossPoint / MAV Matrix Switchers • Operation 3-11