Upper Left X:

00000000h

Upper Left X field specifies X coordinate of upper-left corner of endorser strings rectangle in 1/1200 inch. This field applies signed long integer. This scanner cannot specify Upper Left X coordinate of print position. The 00000000h is regarded as default.

Upper Left Y:

INTERFACE

Upper Left Y field specifies Y coordinate of upper-left corner of endorser strings rectangle to be printed in 1/1200 inch. This field applies signed long integer. This scanner does not check validity in this field.

The base point of endorser string is Upper-Left likewise SET WINDOW. Location of Endorser Strings is different from printer strings. This specifies upper-left corner of the rectangle.

Font:00h(default)

Font field specifies character fonts to be printed. One Endorser Data could have one font.

Table 3.78 Font

Value

Description

 

 

00h

Default

 

 

01h to 7Fh

Reserved

 

 

80h to FFh

Downloaded

Size:00h(default)

Size field specifies character size to be printed in dots. One Endorser Data could have one size available. This field specifies character height in dots. If zero is specified, default is used.

REVS:0b

REVS bit specifies Endorser String is reversed. The Endorser String is printed from last character. This scanner does not support this bit.

M3099GX/GH OEM Manual