Scanning Sequence
Basic Scanning Sequence (Simplex Mode) :
RESERVE UNIT
SET WINDOW(ID:00h)
SEND
OBJECT POSITION
1
(Load Object)
SCAN(ID:00h)
2
READ
OBJECT POSITION
(Unload Object)
RELEASE UNIT
Reserve exclusive use of the scanner.
INTERFACE
Specify document scanning parameter.
Send "Halftone Mask" and/or "Gamma Function" data, if required.
Feed document into ADF.
This command is omissible because SCAN or READ command automatically feeds in a document.
Start scanning operation.
This command is omissible because READ command automatically starts scanning.
Transfer image data from scanner.
READ command would be issued one or more.
The details of READ command sequence is 4.9.5.
Feed out document from ADF.
This command is omissible because end of scanning automatically feeds out document.
Release exclusive use of the scanner.
1This loop is used to scan a batch of document.
2This loop is used to scan a batch of identical format document at maximum speed.