Table 5.1 Device and operator actions for temporary errors (continued)
LCD display | Scanner actions | Action to recover |
|
|
|
|
|
|
HOPPER | [When a read operation is | - The error is |
EMPTY | activated, the pick sensor | recovered by |
| (SPK) goes off but not the | issuing the start |
| hopper empty sensor (SHE) | command. |
| is off.] |
|
| - If an error is detected, the |
|
| hopper table is lowered. |
|
| Then, “Temporary Error” is |
|
| returned to the host |
|
| computer and an error |
|
| message is displayed on |
|
| the LCD display. |
|
| [The hopper empty sensor | - Load documents on |
| (SHE) goes on during | the hopper and |
| reading.] | start reading them. |
| - The read operation is |
|
| terminated normally. |
|
| After the document is |
|
| ejected into the stacker, |
|
| the hopper table is |
|
| lowered. |
|
| When a START, READ, |
|
| or SENSE command is |
|
| received from the host |
|
| computer, “Temporary |
|
| Error” is returned. |
|
| *: This status is not detected |
|
| in the manual mode. |
|
M3099GX/GH OEM Manual |