B3.15 Setting picking time

When you set the picking time, you must set as follows.

<< SETUP MODE >>

PICK TIMER

Screen 30

<< SETUP MODE >>

X X . X S

Screen 31

fAt Screen 2, press [Mode 1] fifteen times to go to the PICK TIMER screen. (Screen 30)

gPress [Mode 2] to see Screen 31. (The default setting is 2 sec.)

hAt Screen 31, press [Mode 1] until the digit you want to change blinks. Then press [Mode 2] until the digit changes as you want. (The specifiable range is from 0.5 to 99.5 sec. in 0.5 sec. step.)

iPress [Mode 1] and [Mode 2] at a time to see Screen 30. The settings are stored to

EEPROM.

jWhen you close the setup mode, go to 9.

B3.16 Setting time-out limit

When you set the time-out limit, you must set as follows.

<< SETUP MODE >>

TIME-OUT SET

Screen 32

TIME-OUT SET

X X X X S

Screen 33

kAt Screen 2, press [Mode 1] sixteen times to go to the TIME-OUT SET screen. (Screen 32)

lPress [Mode 2] to see Screen 33. (The default setting is 30 sec.)

mAt Screen 33, press [Mode 1] until the digit you want to change blinks. Then press [Mode 2] until the digit changes as you want. (The specifiable range is from 1 to 1999 sec. in 1 sec. step.)

nPress [Mode 1] and [Mode 2] at a time to see Screen 32. The settings are stored to

EEPROM.

oWhen you close the setup mode, go to 9.

B-12

M3099GX/GH OEM Manual