When you set the picking time, you must set as follows.
<< SETUP MODE >>
PICK TIMER
Screen 30
<< SETUP MODE >>
X X . X S
Screen 31
fAt Screen 2, press [Mode 1] fifteen times to go to the PICK TIMER screen. (Screen 30)
gPress [Mode 2] to see Screen 31. (The default setting is 2 sec.)
hAt Screen 31, press [Mode 1] until the digit you want to change blinks. Then press [Mode 2] until the digit changes as you want. (The specifiable range is from 0.5 to 99.5 sec. in 0.5 sec. step.)
iPress [Mode 1] and [Mode 2] at a time to see Screen 30. The settings are stored to
EEPROM.
jWhen you close the setup mode, go to 9.
When you set the
<< SETUP MODE >>
Screen 32
X X X X S
Screen 33
kAt Screen 2, press [Mode 1] sixteen times to go to the
lPress [Mode 2] to see Screen 33. (The default setting is 30 sec.)
mAt Screen 33, press [Mode 1] until the digit you want to change blinks. Then press [Mode 2] until the digit changes as you want. (The specifiable range is from 1 to 1999 sec. in 1 sec. step.)
nPress [Mode 1] and [Mode 2] at a time to see Screen 32. The settings are stored to
EEPROM.
oWhen you close the setup mode, go to 9.