Table 3.30 Implementation of SK(Sense Key), ASC(Additional Sense Code), ASCQ(Additional Sense Code Qualifier) Hierachy.
Sense | Additional | Additional | Description |
key | Sense Code | Sense Code |
|
|
| Qualifier |
|
|
|
|
|
0 | 00h | 00h | No Sense |
|
|
|
|
2 | 00h | 00h | Not Ready |
|
|
|
|
| 80h | 01h | Interlock Switch Is Opened |
3 | 80h | 01h | Jam*1 |
|
|
|
|
|
| 02h | ADF Cover Open |
|
|
|
|
|
| 03h | Chuter Out Of Paper |
|
| 04h | Job Separation Sheet detected |
|
|
|
|
| 80h | 08h | Roller unit not set |
|
|
|
|
| 80h | 10h | Print Head on Endorser check |
| 43h | 00h | MESSAGE ERROR |
|
|
|
|
4 | 44h | 00h | Internal Target Failure |
|
|
|
|
| 80h | 01h | FB Motor Fuse Blown |
|
| 02h | Heater Fuse Blown |
|
|
|
|
|
| 03h | Lamp Fuse Blown |
|
|
|
|
|
| 04h | ADF Motor Fuse Blown |
|
| 05h | Mechanical System Failure |
|
|
|
|
|
| 06h | Optical System Failure |
|
|
|
|
| 80h | 10h | Endorser Failure |
| 80h | 11h | Endorser Fuse Blown |
|
|
|
|
5 | 20h | 00h | INVALID COMMAND OPERATION |
|
|
| CODE |
|
|
|
|
| 24h | 00h | INVALID FIELD IN CDB |
|
|
|
|
| 25h | 00h | LOGICAL UNIT NOT SUPPORTED |
|
|
|
|
| 26h | 00h | INVALID FIELD IN PARAMETER |
|
|
| LIST |
|
|
|
|
| 2Ch | 02h | INVALID COMBINATION OF |
|
|
| WINDOWS SPECIFIED |
|
|
|
|
*1 If this unit detects a
M3099GX/GH OEM Manual |