Table 3.30 Implementation of SK(Sense Key), ASC(Additional Sense Code), ASCQ(Additional Sense Code Qualifier) Hierachy.

Sense

Additional

Additional

Description

key

Sense Code

Sense Code

 

 

 

Qualifier

 

 

 

 

 

0

00h

00h

No Sense

 

 

 

 

2

00h

00h

Not Ready

 

 

 

 

 

80h

01h

Interlock Switch Is Opened

3

80h

01h

Jam*1

 

 

 

 

 

 

02h

ADF Cover Open

 

 

 

 

 

 

03h

Chuter Out Of Paper

 

 

04h

Job Separation Sheet detected

 

 

 

 

 

80h

08h

Roller unit not set

 

 

 

 

 

80h

10h

Print Head on Endorser check

 

43h

00h

MESSAGE ERROR

 

 

 

 

4

44h

00h

Internal Target Failure

 

 

 

 

 

80h

01h

FB Motor Fuse Blown

 

 

02h

Heater Fuse Blown

 

 

 

 

 

 

03h

Lamp Fuse Blown

 

 

 

 

 

 

04h

ADF Motor Fuse Blown

 

 

05h

Mechanical System Failure

 

 

 

 

 

 

06h

Optical System Failure

 

 

 

 

 

80h

10h

Endorser Failure

 

80h

11h

Endorser Fuse Blown

 

 

 

 

5

20h

00h

INVALID COMMAND OPERATION

 

 

 

CODE

 

 

 

 

 

24h

00h

INVALID FIELD IN CDB

 

 

 

 

 

25h

00h

LOGICAL UNIT NOT SUPPORTED

 

 

 

 

 

26h

00h

INVALID FIELD IN PARAMETER

 

 

 

LIST

 

 

 

 

 

2Ch

02h

INVALID COMBINATION OF

 

 

 

WINDOWS SPECIFIED

 

 

 

 

*1 If this unit detects a double-feed status while the double-feed detection function is validated for GH/G, a paper jam is reported to the host.

3-54

M3099GX/GH OEM Manual