Table 3.7 Operation Code Types |
|
|
| |
|
|
|
|
|
Command | Operation | Description |
|
|
| Code(hex) |
|
|
|
|
|
|
|
|
RESERVE UNIT | 16 | Reserve a logical unit |
|
|
|
|
|
|
|
RELEASE UNIT | 17 | Release a previously reserved logical |
|
|
|
| unit |
| INTERFACE |
|
|
|
|
|
INQUIRY | 12 | Requests information regarding |
|
|
|
| parameters of target and its attached |
|
|
|
|
| ||
|
| peripheral device(s). |
|
|
REQUEST SENSE | 03 | Requests the target transfer sense |
|
|
|
| data to the initiator |
|
|
|
|
|
|
|
SEND DIAGNOSTIC | 1D | Request the target to perform |
|
|
|
| diagnostic operations on itself |
|
|
|
|
|
|
|
ENDORSER | C1 | Start/Stop endorser function |
|
|
TEST UNIT READY | 00 | Check if the logical unit is ready |
|
|
|
|
|
|
|
SET WINDOW | 24 | Specify windows within the |
|
|
|
| scanning range of the device. |
|
|
|
|
|
|
|
SEND | 2A | Transfers data from initiator to |
|
|
|
| target |
|
|
OBJECT POSITION | 31 | Provids positioning functions (ADF |
|
|
|
| Feed in/out) |
|
|
|
|
|
|
|
SCAN | 18 | Requests the target begin a scan |
|
|
|
| operation |
|
|
|
|
|
|
|
READ | 28 | Requests the target transfer data to |
|
|
|
| the initiator |
|
|
MODE SELECT(6) | 15 | Specify logical unit, peripheral |
|
|
|
| device parameters from the initiator |
|
|
|
| to the target |
|
|
|
|
|
|
|
MODE SENSE(6) | 1A | Report parameters from the target to |
|
|
|
| the initiatot |
|
|
|
|
|
|
|
M3099GX/GH OEM Manual |