Table 3.15 FunctionBit Description

Bit 0 Data Over Flow

Scanners that will cause data over flow sets this bit to 1. Image scanners that will not cause data over flow set this bit to 0. Support of Start Switch is not specified.

Bit 1 Binary (Black and White)

Scanners support Black and White set this bit to 1. Scanners do not support Black and White set this bit to 0.

Bit 2 Dither/Halftone

Scanners support Dither/Halftone set this bit to 1. Scanners do not support Dither/Halftone set this bit to 0.

Bit 3 Grayscale

Scanners support Grayscale set this bit to 1. Scanners do not support Grayscale set this bit to 0.

Steps of gray is not specified.

Bit 4 Reserved (Bit 4 to 7 are Reserved in JBMS)

Bit 5 Binary (RGB Color)

Scanners support (RGB Color) set this bit to 1. Scanners do not support (RGB Color) set this bit to 0.

Bit 6 Dither/Halftone(RGB Color)

Scanners support Dither/Halftone (RGB Color) set this bit to 1. Scanners do not support Dither/Halftone (RGB Color)set this bit to 0.

Bit 7 Grayscale(RGB Color)

Scanners support Grayscale(RGB Color) set this bit to 1. Scanners do not support Grayscale(RGB Color) set this bit to 0. Steps of gray is not specified.

*) Data Over Flow means when receipt of data by the initiator is too slow, data buffer of image scanner is filled and data is not guranteed.

Fujitsu further defines own Vital Product Data using Vendor Specific field of JBMS. This extended Vital Product Data is used by Device Driver to confirm which functions are supported. Current defined data is totally 100 bytes but it will be expanded by future functions.

3-40

M3099GX/GH OEM Manual