Power-On to Selection Time

The recommended maximum time from power application until an SCSI target is able to respond with appropriate status and sense data to the TEST UNIT READY, INQUIRY, and REQUEST SENSE commands.

Reset to Selection Time

The recommended maximum time after a hard RESET condition until an SCSI target is able to respond with appropriate status and sense data to the TEST UNIT READY, INQUIRY, and REQUEST SENSE commands.

Reset Hold Time

The minimum time for which RST is asserted. There is no maximum time.

Selection Abort Time

The maximum time that a target (or initiator) shall take from its most recent detection of being selected (or reselected) until asserting a BSY response. This time-out is required to ensure that a target (or initiator) does not assert BSY after a SELECTION (or RESELECTION) phase has been aborted. This is not the selection time-out period; see ANSI SCSI-2 6.1.3.1. and ANSI SCSI-2 6.1.4.2. for a complete description.

Selection Time-out Delay

The minimum time that a SCSI device should wait for a BSY response during the SELECTION or RESELECTION phase before starting the time-out procedure. Note that this is only a recommended time period.

3-14