| Table 3.18 Implemented Standard Command |
|
|
|
|
| |
|
|
|
|
|
|
|
|
| Bit | Command | Code |
|
|
|
|
|
|
|
|
|
|
|
|
| 0 | TEST UNIT READY | 00h | M |
|
|
|
|
|
|
|
|
|
|
|
| 1 | REQUEST SENSE | 03h | M |
|
|
|
|
|
|
|
|
|
|
|
| 2 | INQUIRY | 12h | M |
|
|
|
|
|
|
|
|
|
| INTERFACE |
| 3 | MODE SELECT(6) | 15h | O |
|
| |
|
|
|
| ||||
|
|
|
|
|
|
|
|
| 4 | RESERVE UNIT | 16h | M |
|
|
|
| 5 | RELEASE UNIT | 17h | M |
|
|
|
|
|
|
|
|
|
|
|
| 6 | COPY | 18h | O |
|
|
|
|
|
|
|
|
|
|
|
| 7 | MODE SENSE(6) | 1Ah | O |
|
|
|
|
|
|
|
|
|
|
|
| 8 | SCAN | 1Bh | O |
|
|
|
|
|
|
|
|
|
|
|
| 9 | RECEIVE DIAGNOSTIC RESULTS | 1Ch | O |
|
|
|
|
|
|
|
|
|
|
|
| 10 | SEND DIAGNOSTIC | 1Dh | M |
|
|
|
|
|
|
|
|
|
|
|
| 11 | SET WINDOW | 24h | M |
|
|
|
|
|
|
|
|
|
|
|
| 12 | GET WINDOW | 25h | O |
|
|
|
|
|
|
|
|
|
|
|
| 13 | READ | 28h | M |
|
|
|
|
|
|
|
|
|
|
|
| 14 | SEND | 2Ah | O |
|
|
|
|
|
|
|
|
|
|
|
| 15 | OBJECT POSITION | 31h | O |
|
|
|
|
|
|
|
|
|
|
|
| 16 | GET DATA BUFFER STATUS | 34h | O |
|
|
|
|
|
|
|
|
|
|
|
| 17 | COMPARE | 39h | O |
|
|
|
|
|
|
|
|
|
|
|
| 18 | COPY AND VERIFY | 3Ah | O |
|
|
|
|
|
|
|
|
|
|
|
| 19 | WRITE BUFFER | 3Bh | O |
|
|
|
|
|
|
|
|
|
|
|
| 20 | READ BUFFER | 3Ch | O |
|
|
|
|
|
|
|
|
|
|
|
| 21 | CHANGE DEFINITION | 40h | O |
|
|
|
|
|
|
|
|
|
|
|
| 22 | LOG SELECT | 4Ch | O |
|
|
|
|
|
|
|
|
|
|
|
| 23 | LOG SENSE | 4Dh | O |
|
|
|
|
|
|
|
|
|
|
|
| 24 | MODE SELECT(10) | 55h | O |
|
|
|
|
|
|
|
|
|
|
|
| 25 | MODE SENSE(10) | 5Ah | O |
|
|
|
|
|
|
|
|
|
|
|
| 26 | Reserved |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 27 | Reserved |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 28 | Reserved |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 29 | Reserved |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 30 | Reserved |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 31 | Reserved |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
M3099GX/GH OEM Manual |