Furuno 1934C-BB, GD-1920C-BB, 1954C-BB Sounder function key menu, Sounder function key options

Models: GD-1920C-BB 1934C-BB 1834C-BB 1824C-BB 1954C-BB 1944C-BB 1964C-BB

1 236
Download 236 pages 56.87 Kb
Page 193
Image 193

7. CUSTOMIZING YOUR UNIT

7.9.4Function key setup

The function keys provide one-touch execution of a desired function. The default sounder function key settings are as shown in the table below.

Function Key

Default Function

1

Output current position.

2

Suppress clutter.

3

Erase weak signal.

4

Suppress noise.

5

Set picture advancement speed.

 

 

Function Key Label

TLL

CLT

SLV

NL

PA

If the above settings are not to your liking you may change them as follows:

1.Show the sounder display.

2.Press the MENU key.

3.Press the D: FUNCTION KEY SETUP soft key.

Function key setting

Function key label

SOFT KEY 1

TLL: TLL OUTPUT

SOFTKEY 2

CLT: CLUTTER

SOFT KEY 3

SLV: SIGNAL LEVEL

SOFT KEY 4

NL: NOISE LIMITER

SOFT KEY 5

PA: PICTURE ADV

T

L

L

C

L

T

S

L

V

N

L

P

A

FUNC

KEY

A EDIT

E RETURN

Sounder function key menu

4. Select the function key you want to program, then press the A: EDIT soft key.

SOFT KEY 1

OFF

MOD: AUTO MODE

GHF: GAIN - HF

GLF: GAIN - LF

SFT: SHIFT

NL: NOISE LIMITER

CLT: CLUTTER

WMK: WHITE MARKER

HUE: HUE

SLV: SIGNAL LEVEL

Scroll down

SOFT KEY 1

PA: PICTURE ADV

TG: TEMP. GRAPH

TVH: TVG - HF

TVL: TVG - LF

EOH: OFFSET - HF

EOL: OFFSET - LF

SMT: SMOOTHING

ZMR: ZOOM RANGE

BLR: B/L RANGE

TLL: TLL OUTPUT

Scroll down

SOFT KEY 1

SSR: SNDR SOURCE

DBX: D. BOX ON/OFF

CHG: CHANGE CNTRL

SAV: SAVE SCREEN

QP: QUICK POINT

MRK: MARK ENTRY

Sounder function key options

5.Select function desired with the Trackball, then press the C: ENTER soft key or ENTER knob to register your selection.

6.Press the MENU key to close the menu.

7-36

Page 193
Image 193
Furuno 1934C-BB, GD-1920C-BB, 1954C-BB, 1964C-BB, 1944C-BB, 1834C-BB Sounder function key menu, Sounder function key options