Furuno GD-1920C-BB, 1954C-BB, 1964C-BB, 1944C-BB, 1934C-BB, 1834C-BB, 1824C-BB manual Transceiver Module

Models: GD-1920C-BB 1934C-BB 1834C-BB 1824C-BB 1954C-BB 1944C-BB 1964C-BB

1 236
Download 236 pages 56.87 Kb
Page 224
Image 224

3

TRANSCEIVER MODULE

3.1

Frequency and Modulation 9410 MHz ±30MHz (X band), P0N

3.2

Peak Output Power

M1824C-BB: 2.2 kW nominal

 

 

M1834C-BB /1934C-BB: 4 kW nominal

 

 

M1944C-BB: 6 kW nominal

 

 

M1954C-BB: 12 kW nominal

 

 

M1964C-BB: 25 kW nominal

3.3

Modulator

FET Switching Method

3.4Intermediate Frequency 60 MHz

3.5

Tuning

Automatic or manual

3.6

Receiver Front End

MIC (Microwave IC)

3.7

Bandwidth

Tx pulselength 0.08 s and 0.3 s: 25 MHz

 

 

Tx pulselength 0.8 s: 3 MHz

3.8

Duplexer

Circulator with diode limiter

3.9

Warming up

90 s approx.

4

INTERFACE

 

4.1

Input Data

IEC 61162-1 (NMEA 0183 Ver1.5/2.0)

 

Own ship’s position:

GGA>RMC>RMA>GLL

 

Ship’s speed:

RMC>RMA>VTG>VHW

 

Bearing (True):

HDT>HDG*1>HDM*1>VHW

 

Bearing (Magnetic):

HDM>HDG*1>HDT*1>VHW

 

Course:

RMC>RMA>VTG

 

Water depth:

DPT>DBT>DBS>DBK

 

Wind:

MWV>VWT>VWR

 

Water Temperature:

MTW

 

Time:

ZDA

 

*1: calculated by magnetic deviation

4.2 Output Data

 

 

Alarm signal

12 VDC, 100 mA or less

 

NMEA 0183 Ver1.5

GGA, GLL, RMA, RMC, GTD, VTG, ZDA (GPS data required)

 

 

RMB, WPL, BWC or BWR, APB, AAM, BOD, XTE, VHW,

 

 

MTW, DPT or DBT, DBS (ETR required),

 

 

TLL (L/L, Heading data required), TTM (ARPA required)

SP - 3

Page 224
Image 224
Furuno GD-1920C-BB, 1954C-BB, 1964C-BB, 1944C-BB, 1934C-BB, 1834C-BB, 1824C-BB manual Transceiver Module