Pos

Chars

Parameters

 

 

 

 

 

 

 

Three digit number shows total scans-on-

C

67

3

code.

D

70

3

000-999; Good Quiet Zones (scans)

 

 

 

Two digit number shows Lead QZ. Units:

E

73

2

.1X (00-9A)

 

 

 

Two digit number shows Trail QZ. Units:

F

75

2

.1X (00-9A)

 

 

 

One digit number: ‘0’ (off), ‘1’ (on). Sync

G

77

1

state.

 

 

 

IGC, two bytes: Units of X dimension times

H

78

2

10. Value = 00 when N/A

 

 

 

Two digits; Percent of good global

I

80

2

thresholds. (00-9A)

 

 

 

Two digits; Calculated application

J

82

2

checksum value or Code 93 mod check K

 

 

 

One digit; indicates the subsymbology

 

 

 

enabled in the y field of ~LFxy command for

 

 

 

this symbol. A value of 0 indicates no

O

84

1

subsymbology check is enabled.

 

 

 

One digit; Buffer overrun indication; 0 = no

K

85

1

overrun

L

86

2

Two digits; Decode header indicator "^^"

[chars]

88

...

Bar code data characters (variable length).

 

 

 

Programmable ASCII character indicates

 

 

 

end of transmit; See ~SSbbbeee (page 6-

 

 

 

28) command. LF (line feed) required for

Z

last

1

ScanView.

y* - The symbology identifiers use groups of numbers to identify each symbology. The range of possible values could potentially span 100 for each symbology category. The Symbology Identifier Table lists each identifier group with the corresponding symbology.

*A no read condition is indicated by all four bytes yy, M and N set to 0 in a transmission. All other data is therefore not valid.

See the ~OS# command (page 6-18) for other transmission data formats.

Symbology Identifier Table

Identifiers

Symbology Category

 

 

02

I 2 of 5

 

 

03

Code 128

 

 

04

Code 93

 

 

3 - 4

Quick Check® SV Series User’s Guide

Page 22
Image 22
HandHeld Entertainment SV Series manual Symbology Identifier Table