c.Overall ISO Grade (Programmable, ~LAxx)

d.Bad quiet zone (~PB816xxx000)

e.No Read (if sync is received)

f.Partial decodes and % decode logic programmable (~Lp#, ~Lq#)

g.Number of codes per sync programmable (~LN##, ~LZ##)

h.Symbology modulo check digit

3.Sync polarity - Leading edge high going; time between trailing (low going) edge to leading edge - 12.5 milliseconds minimum

4.Port 1; acts as strobe (signal ensuring Port 3 condition is stable) in response to trailing edge of sync input. This signal will go “on” (sink current) between 20 and 100 microseconds after Port 3 condition is stable.

5.Ports 1 and 3 will go high (no current) within 12.5 milliseconds after the sync input goes high (leading edge).

6.Use ~PR0200 for proper port initialization.

Mode 02 LED Operation

1.LED1 will turn on if Port 3 goes active due to ISO or quiet zone failures

2.LED2 will turn on if Port 3 goes active due to a no read or partial condition

3.The leading edge of a sync input will turn LEDS 1 and 2 OFF.

SV Commands Important to Mode 02

This system is operating in a “mode” rather than fully programmable logic. The port activation parameters are programmable via the ~PB8 rather than ~PB1, ~PB2, etc. for each individual port. Other commands, such as mode commands are also available. The commands most useful for this system application are described below.

~LV02

This command sets this mode of operation.

~Lp0

This command turns off all partial decode logic at the decoder level

~Lp1

This command turns on partial decode logic at the decoder level

~LQ1

This command allows partial decodes to activate the output ports

6 - 34

Quick Check® SV Series User’s Guide

Page 82
Image 82
HandHeld Entertainment SV Series manual Mode 02 LED Operation, ~LV02