Scanning Performance–SV Series Model
| SV100 | SV100HD | SV100C | ||
|
|
|
|
|
|
Analyses/ | 100 | 100 | 100 | 200 | 200 |
sec |
|
|
|
|
|
|
|
|
|
|
|
Scan | 6” | 4.5” | 10.5” | 2.5” | 1.75” |
Width | (152mm) | (114mm) | (267mm) | (63.5mm) | (44mm) |
|
|
|
|
|
|
Focus | 8” | 6” | 15” | 8” | 6” |
Distance | (203mm) | (152mm) | (381mm) | (203mm) | (152mm) |
|
|
|
|
|
|
X dim | .0067” | .005” | .013” | .0067” | .005” |
(min) | (.17mm) | (.127mm) | (.33mm) | (.17mm) | (.127mm) |
|
|
|
|
|
|
Note: All Models - 4 bar codes across maximum (picket fence direction)
Scanner Options
Scanners can incorporate options for special optics and/or be focused for special applications. Contact Hand Held Products Technical Assistance (see page
•High Density Focus: Analyze bar codes with 5 mil X dimension
•Custom focus distances are available to achieve various spot sizes
Power
•+5 volts DC, ± .25 volt
•1 amp maximum
Sync
See "Sync Inputs" on page 2-2 for more details
I/O connector pin 4 input:
•TTL switching level threshold
•Maximum input voltage swing: +/- 12 VDC
•100 K ohm internal
I/O connector pins 1 (+), 2
•24 volts DC nominal input for sensing
•30 volts DC maximum input, approximately 15 volts minimum for sensing
•This input is ground isolated from 5 VDC power
8 - 2 | Quick Check® SV Series User’s Guide |