Legal values for each parameter are:

Y

a

b

c

d

e

f

g

h

i

j

k

l

m

n

o

Pos

Chars

Parameters

 

 

Programmable ASCII character indicates

 

 

start of transmit:

 

 

See ~SSbbbeee (page 6-28) command.

 

 

CR (carriage return) required for Scan-

1

1

View.

 

 

P=PASS Ref Decode, F=FAIL per Ref

 

 

Decode algorithm. P and F are a majority

2

1

decision over all scans.

 

 

00-9A (0-100); Decodability calc. avg.

3

2

over all decoded scans

 

 

00-9A; Modulation calc. avg. over all

5

2

decoded scans

 

 

0-9A; Defects calc. avg. over all decoded

7

2

scans

 

 

00-9A; Edge Contrast calc. avg. over all

9

2

decoded scans

 

 

0-9A; Rmin/Rmax calc. avg. over all

11

2

decoded scans

 

 

00-9A; SymbolContrast calc. avg. over all

13

2

decoded scans

 

 

00-9A; PCS calc. avg. over all decoded

15

2

scans

 

 

00-9A; R(white) calc. avg. over all

17

2

decoded scans

 

 

00-9A; R(black) calc. avg. over all

19

2

decoded scans

 

 

00-99; Ratio calc. avg. over all decoded

 

 

scans. Example: 29 represents a ratio of

21

2

2.9

 

 

+ or - indicating sign of avg. bar deviation

23

1

calculation. + indicates wide bars.

 

 

Bar deviation calculation averaged over all

 

 

decoded scans. Units are % of X. Value:

24

2

00-9A (signify 0 – 100)

 

 

+ or - indicating sign of avg. min. bar

 

 

deviation calculation. + indicates wide

26

1

bars.

 

 

Minimum bar deviation calculation

 

 

averaged over all decoded scans. Units

27

2

are in % of X. Value: 00-9A (signify 0 –100)

 

 

 