Mode 01 (~LV01)

Mode 01 I/O operation

1.System will operate in Edge Sync or Envelope sync mode (~LX#)

2.Sync polarity programmable (~LP#)

3.Use ~PR0210 for proper port initialization.

4.Port 1 will go active OFF (no current) on an error condition.

5.Port 2 will go active ON (sink current) on an error condition.

6.Pushing the reset button or power re-cycle will place Ports 1 and 2 in their inactive states and reset the # codes per sync counter.

7.Error conditions available are:

a.Partial Read (Programmable, ~LQ#, ~Lp#)

b.% decode (Programmable, ~LD##)

c.Bad Quiet Zone (~PB816xxx100)

d.ISO Defects grade (Programmable, ~PB806xxx000)

e.ISO Decodability (Programmable, ~PB802xxx100)

f.Symbol Contrast grade (Programmable, ~PB804xxx100)

g.No Read (if sync is received)

h.Number of codes per sync programmable (~LN##, ~LZ##)

i.Overall ISO Grade (Programmable, ~LAxx)

j.Symbology modulo check digit

Mode 01 LED Operation

1.LED1 will turn on if Outputs 1 and 2 go active due to ISO, contrast, or quiet zone failure

2.LED2 will turn on if Outputs 1 and 2 go active due to a partial or no read condition

Quick Check® SV Series User’s Guide

6 - 31

Page 79
Image 79
HandHeld Entertainment SV Series manual Mode 01 ~LV01, Mode 01 I/O operation, Mode 01 LED Operation