~LAxx
This command sets the passing threshold for the Overall ISO method Symbol Grade. For example: ~LA28 causes an Overall Symbol Grade of 2.7 or lower calculated for the code analyzed to set a failure condition for this parameter.
~Hx
This command stores all parameters into
Mode 16 (~LV16)
Mode 16 I/O operation
1.System will operate in Edge Sync or Envelope sync mode (~LX#).
2.Sync polarity programmable (~LP#)
3.Use ~PR0200 for proper port initialization.
4.Port 1 will pulse active ON for a bar code quality error condition.
5.Port 2 will pulse active ON for a NO READ, partial or low % decode error condition.
6.Port 3 will pulse active ON for a
7.Port pulse times programmable. (~PP801xxx)
8.Pulses act like
9.Pushing the reset button or power
10.Error conditions available are:
a.Partial Read (Programmable, ( ~Lp#, LQ#)
b.% decode (Programmable, ~LD##)
c.Bad Quiet Zone: < 10X (~PB816xxx100)
d.ISO Defects grade less than B (Programmable, ~PB806xxx000)
e.ISO Decodability grade less than C (Programmable, ~PB802xxx100)
f.Symbol Contrast grade less than D (Programmable, ~PB804xxx100)
g.Overall ISO Grade (Programmable, ~LAxx)
h.No Read (if sync is received)
i.Number of codes per sync programmable (~LN##, ~LZ##)
Quick Check® SV Series User’s Guide | 6 - 39 |