11.Error conditions available are:

a.Partial Read (Programmable, ( ~Lp#, LQ#)

b.% decode (Programmable, ~LD##)

c.Bad Quiet Zone: < 10X (~PB816xxx100)

d.ISO Defects grade (Programmable, ~PB806xxx000)

e.ISO Decodability grade (Programmable, ~PB802xxx100)

f.Symbol Contrast grade (Programmable, ~PB804xxx100)

g.Overall ISO Grade (Programmable, ~LAxx)

h.No Read (if sync is received)

i.Number of codes per sync programmable (~LN##, ~LZ##)

j.X dimension Range (Programmable ~PB811xxxyyy)

k.Ratio (Programmable ~PB815xxx000)

l.Symbology Mod Check data error

m.I 2 of 5 optional Mod 10 Check Digit data error (if enabled)

n.Data Match Error (~BC)

o.Increment or Decrement data error (~Br)

LED Operation

1.LED1 will turn on when Ports 1 and 2 are active due to ISO, Symbol Con- trast, X dimension, ratio, mod check or quiet zone error conditions.

2.LED1 will flash when Ports 1 and 2 are active due to a data increment or decrement error condition.

3.LED2 will turn on when Ports 1 and 2 are active due to a partial, % decode or no read error conditions.

4.LED2 will flash when Ports 1 and 2 are active due to a Data Match error condition.

5.Flashing indication will override a solid on indication if both types of error conditions occur.

Note: Both LEDs can be on in cases where multiple bar codes are analyzed in a sync period.

6 - 46

Quick Check® SV Series User’s Guide

Page 94
Image 94
HandHeld Entertainment SV Series manual LED Operation