[~SN###]#scans= 050 [~Lp#]part= 000 [~Lt#]itfp= 001 [DACs]= 175 156 255 255 [~LQ#]p_out= 000 [~Lw,d]def= 000 000 [~L*]pnet= 000 [~LC##]I25min= 002 [~H###]NTrys= 010 [~OS#]Data_Output= 000 [~Hs#]RunSpeed= 000 [~SS######]CntlChars=01 3 010 {hex 5}
T
~Hdx01nnn
Sets scanner gain or offset.
x = value of 1 or 2. If =1, scanner gain is set. If = 2, scanner offset is set.
nnn = gain or offset setting.
For gain, the higher the value, the higher the gain. 225 is the max allowed value.
Example: ~Hd101195 sets the scanner gain setting to a value of 195.
For offset, the higher the value, the lower the offset.
Example: ~Hd201145 sets the scanner offset value to 145.
These commands are best used in conjunction with Hand Held Products’ ScanView software. Please refer to Chapter 4 for descriptions on the use of these commands.
~Hnx
Sets the number of consecutive scans that do not detect a bar code that cause a bar code to exit the beam and be reported.
x = values of 2, 3, 4 or 5. The normal setting is 5.
This command is best used in conjunction with the ~SB 1 setting for single scan operation. Please see ~SBn (page
~Hx
Saves the parameters to FLASH
6 - 10 | Quick Check® SV Series User’s Guide |