Chapter 4 Product lineup and wiring

4.3 14-Point Basic Unit

Name and function of each part

Type

EH-*14***

10] Terminal cover

 

5] Input terminals

 

 

 

 

1] POW LED

 

 

2] OK LED

 

 

3] RUN LED

11] Mounting hole

 

8] Expansion

 

connector cover

 

 

 

 

9] DIP SW cover

 

 

6] Output terminals

4] Serial port cover

12] DIN rail installation clip

 

7] Power terminal

No.

Item

Detailed explanation

 

 

 

 

 

 

 

 

 

 

Remarks

Explanation of operation

Operations are performed according to the contents of the program created

 

 

 

by the user.

 

 

 

 

 

 

 

 

 

 

 

 

 

The programming unit connected to the CPU module communication port

 

 

 

writes and reads the user programs.

 

 

 

 

 

 

 

 

 

 

 

 

 

Memory is installed inside the CPU module in which the user programs and

 

 

 

internal output information are stored.

 

 

 

 

 

 

 

 

 

 

 

1]

POW LED

Lighting when the power is supplied.

 

 

 

 

 

 

 

 

 

 

 

2]

OK LED

Lighting at normal operation.

 

 

 

 

 

 

 

 

 

 

See Chapter 12.

3]

RUN LED

Lighting at RUN status.

 

 

 

 

 

 

 

 

 

 

 

4]

Serial port cover

Cover for the connector for connecting

 

 

 

 

 

 

 

 

 

 

See Chapters 8 and 11.

STOP

RUN

 

 

 

peripheral units and the RUN switch.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When the cover is opened, the RUN switch,

 

 

 

 

 

 

 

VR1

VR2

 

 

 

 

potentiometers (VR), and RS-232C serial port 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(PORT 1) can be used.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PORT1

 

 

 

 

 

 

 

 

The communication specification is set to port 1.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5]

Input terminals

Terminals for wiring the external input units.

 

 

 

 

 

 

 

 

 

 

See Chapter 10.

 

 

Recommended terminals are shown in the

 

 

 

 

 

 

6

(Make sure that the terminals will not

 

 

 

 

 

 

 

 

 

 

figure to the right.

 

 

 

 

 

 

 

 

 

 

 

disengage due to loose screws.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

One piece of AWG14 to AWG22 (2.1 to

 

 

 

 

 

 

 

 

 

 

 

 

 

0.36 mm2) or two pieces of AWG16 to

 

 

 

 

 

 

6

(Recommended)

 

 

AWG22 (1.3 to 0.36 mm2) per terminal may

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

be wired.

 

 

 

 

 

 

 

 

 

 

 

6]

Output terminals

Terminals for connecting the external load.

 

 

 

 

 

 

 

 

 

 

See Chapter 10.

 

 

The wiring specification is the same as for the input terminals.

 

 

 

 

 

 

7]

Power terminal

Terminal for connecting the power supply.

 

 

 

 

 

 

 

 

 

 

See Chapter 10.

 

 

The wiring specification is the same as for the input terminals.

 

 

 

 

 

 

8]

Expansion cover

Cover for the expansion connector

 

 

 

 

 

 

 

 

 

 

See Chapter 10.

9]

DIP SW cover

Cover for the DIP switches

 

 

 

 

 

 

 

 

 

 

See Chapter 11.

 

 

When the cover is opened, the DIP switches are exposed. These DIP

 

 

 

switches are used to set the communication speed of serial port 1 and the

 

 

 

modem connection.

 

 

 

 

 

 

 

 

 

 

 

10]

Terminal cover

Cover for terminals

 

 

 

 

 

 

 

 

 

 

 

11]

Mounting hole

Used when installing the PLC with screws

 

 

 

 

 

 

 

 

 

 

See Chapter 10.

12]

DIN rail

Used when installing the PLC on a DIN rail

 

 

 

 

 

 

 

 

 

 

See Chapter 10.

 

installation clip

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4-4

Page 36
Image 36
Hitachi NJI-350B manual Point Basic Unit, EH-*14