Chapter 13 Troubleshooting

(2)Corrective actions when an error occurred

The process flow when an error occurred is shown below.

Error occurred

Error is detected by the CPU module and displayed by lit/flashing/not lit of RUN and OK LEDs.

Verify the self-diagnostic error code (WRF000) with the RUN and OK

LED statuses or using a peripheral unitand refer to error code list.

Reference the bit special

Reference the word

internal output (14-1).

special internal output

 

 

(14-2).

 

 

 

 

 

 

 

Reference the grammar/

 

 

assemble error (WRF001)

 

 

detailed data (13-2) and

 

 

remove the error cause.

 

 

 

 

Reference the operation error (WRF015) detailed data (13-3) and remove the error cause.

Remove the error cause according to the corrective action for each error code as shown below.

 

If there are spare parts available, replace the parts.

 

Contact our service

 

 

 

 

 

 

department.

 

 

 

 

Error code

Error name

Corrective action

 

11

System ROM error

Restart the power.

 

12

System RAM error

If the same error occurs, it is a hardware error in the CPU module, so replace the CPU module

13

Microcomputer error

with a spare.

 

1F

System program error

Make sure that there are no machines, etc. that generate excessive noise near MCRO-EH.

 

 

 

23

Undefined instruction

Note: The 1x error cannot be verified since peripheral units cannot be connected until the

27

Data memory error

system starts up after powering on again.

 

 

 

 

Power shut-off, power

Check the power supply voltage of the basic unit and expansion unit.

 

supply error

 

 

 

31

User memory error

The contents of the user program is destroyed. Perform initialization and transfer the program

 

 

again.

 

 

 

This is displayed when the machine is stored with a worn-out battery or without battery for a

 

 

long period of time.

 

33

User memory size

This may be displayed when the contents of the memory within the basic unit is unstable.

 

error

If the same error occurs after initialization, replace the basic unit with a new one.

34

Syntax/assembler

There is a syntax/assembler error in the user program.

 

 

error

Verify the program and I/O assignment.

 

41

I/O information

Check the I/O assignment.

 

 

verification error

Check the expansion cable connection.

 

44

Congestion error

Change the program so that the scan time of the user program is less or change the congestion

 

(normal scan)

check time.

 

45

Congestion error

Change the program so that the periodic interrupt program execution time is less.

 

(periodic scan)

 

 

 

46

Congestion error

Perform interlock externally to that the same interrupt will not occur during interrupt

 

(interrupt scan)

processing. Change the program so that the execution time of the interrupt program is short.

5F

Backup memory error

There is a possibility that the FLASH memory cannot be written to. Reset the power after the

 

 

user program is read and saved to the peripheral units.

 

13-3

Page 278
Image 278
Hitachi NJI-350B manual Process flow when an error occurred is shown below, Error code Error name Corrective action, 13-3