Home Automation 1503 Home Automation, Inc, The display should read “WHEN AWAY - ALL OFF”

Models: 1503

1 80
Download 80 pages 51.31 Kb
Page 44
Image 44
The display should read “WHEN AWAY: - ALL OFF”.

Home Automation, Inc.

into the alarm state. So we program button 21 to turn unit 5 on for 5 minutes.

Press PROG, *(button), 2, 1, ENTER, UNIT-NUMBER, 5, TIME, 5, ON.

The display should show “WHEN Z6 ALM: - STAIRWELL ON FOR 5”.

Press ENTER to commit the program to memory.

SECURITY ARMING ACTIVATED BUTTONS

Certain buttons are automati- cally activated upon security arm- ing status changes. These buttons are activated when the system is put in the OFF, HOME, ASLEEP, or AWAY modes. When arming the system into the HOME, ASLEEP or AWAY modes, the button is activated after the EXIT DELAY. Programs that change the security arming mode activate these buttons. Quick arm- ing also activates these buttons.

Table 1 in the Appendix shows which buttons are activated by which zones.

EXAMPLE 3: Program the AWAY mode to turn off all lights and turn on the energy saver (unit 17). From Table 1, we determine that button 178 is activated when the security system is armed in the away mode.

Press PROG, *(button), 1, 7, 8, ENTER, ALL, OFF.

The display should read “WHEN AWAY: - ALL OFF”.

Press ENTER to commit the program to memory. Continue programming:

Press *(button), 1, 7, 8, ENTER, UNIT- NUMBER, 1, 7, ON.

The display should read “WHEN AWAY: - ENERGY SAVER ON”.

Press ENTER to commit the program to memory.

CONDITIONALIZED PROGRAMS

NOTE: In UL Listed Installa- tions, conditionalized programs shall not be used to control the security mode.

Timed programs and event buttons may be conditionalized such that the programmed command is only executed if the specified condition is true. Programs may be conditionalized by:

-Darkness (using the sunrise/ sunset calculation)

-Time Clock 1 - 3 on or off

-Zones closed/secure or open/in alarm

-Security mode (OFF, HOME, ASLEEP, or AWAY).

A program conditional may be specified by selecting the *IF option from the programming menu by pressing the * key. If no condi- tional is specified, the programmed command will always be executed when activated.

To allow a program to only be executed if it is light outside, i.e. after sunrise but before sunset, press *, AM.

To allow a program to only be executed if it is dark outside, i.e. after sunset but before sunrise, press *, PM.

42

Page 44
Image 44
Home Automation 1503 owner manual Home Automation, Inc, The display should read “WHEN AWAY - ALL OFF”

FAQ

How do I program button 21 to turn unit 5 on for 5 minutes?

To program button 21, press PROG, *button, 2, 1, ENTER, UNIT-NUMBER, 5, TIME, 5, ON. Then press ENTER to commit the program to memory.

Which buttons are automatically activated upon security arming status changes?

Certain buttons are activated when the system is put in the OFF, HOME, ASLEEP, or AWAY modes. Table 1 in the Appendix shows which buttons are activated by which zones.

Can conditionalized programs be used to control the security mode in UL Listed Installations?

No, in UL Listed Installations, conditionalized programs shall not be used to control the security mode. Timed programs and event buttons may be conditionalized under specific conditions.