10.UNDERWRITER'S LABORATORIES

Home Automation,

The TIME that was entered before setting an on or off time to NEVER is saved, and will re-appear when a day is set in place of NEVER.

Setting both the DIAL OUT 1 ON and the DIAL OUT 1 OFF times to NEVER will make DIAL OUT NUMBER 1 never active.

DIAL OUT NUMBER 2

DIAL OUT 2 ON

DIAL OUT 2 OFF

DIAL OUT NUMBER 2 can entered into the system and set for time and dates exactly like DIAL OUT NUMBER 1.

The default for DIAL OUT 2 ON is 12:00 AM MTWTFSS, and the default for DIAL OUT 2 OFF is NEVER, so that DIAL OUT NUMBER 2 is always active.

DIAL OUT NUMBER 3

DIAL OUT 3 ON

DIAL OUT 3 OFF

Same as DIAL OUT NUMBER 2.

DIAL OUT NUMBER 4

DIAL OUT 4 ON

DIAL OUT 4 OFF

Same as DIAL OUT NUMBER 2.

10.UNDERWRITER'S LABORATORIES

R E Q U I R E M E N T S

The Model 1503 Version 2, Model 1503-LC, Model 1102 Expansion En- closure and Model 1503A2005 con- soles have been tested and Listed by UL for these applications:

-UL 985, Household Fire Warning System Units

-UL 1023, Household Burglar Alarm System Units

-UL 1635, Digital Burglar Alarm Communicator System Units

-UL 1637, Home Health Care Sig- naling Equipment

When used in a UL Listed Instal- lation, the following items apply:

1.The “High Security Mode” must be ON.

2.The “Enable Auto Bypass” fea- ture must be OFF.

3.The ENTRY DELAY shall not exceed 45 seconds.

4.The EXIT DELAY shall not ex- ceed 60 seconds.

5.Double Delay and Quad Delay zone types shall not be used.

6.Underwriter's Laboratories requires the sounding device to be mounted indoors. If, however, the sounding device is connected to the "EXT HORN" terminals of the Model 1503, then the OUTSIDE SIREN DELAY shall be set to 0.

76

Page 78
Image 78
Home Automation 1503 owner manual R E Q U I R E M E N T S, Underwriters Laboratories, Home Automation

FAQ

What are the requirements for a UL Listed Installation?

The High Security Mode must be ON, the Enable Auto Bypass feature must be OFF, the ENTRY DELAY shall not exceed 45 seconds, the EXIT DELAY shall not exceed 60 seconds, and more.

How can I set the DIAL OUT numbers?

DIAL OUT numbers can be entered into the system and set for time and dates exactly like DIAL OUT NUMBER 1. The defaults for DIAL OUT 2 ON and OFF are 12:00 AM MTWTFSS and NEVER, respectively.

Can I make the DIAL OUT NUMBER 1 inactive?

Setting both the DIAL OUT 1 ON and the DIAL OUT 1 OFF times to NEVER will make DIAL OUT NUMBER 1 never active.