If 115VAC is present on terminal #3 (P) and not on terminal #5 (Y), replace X10 relay. If 115VAC is present on X10 relay terminal #7 (Y) and PM is not energized, check for 115VAC at X10 relay terminal #4 (R) to neutral (W) and terminal #6 (DBU) to neutral

(W). If 115VAC is present on terminal #6 (DBU) and not on terminal #4 (R), replace X10 relay. If 115VAC is present on X10 relay terminal #4 (R), check control switch contact continuity between terminals #4 (R) and #5 (R). If contacts are open, replace control switch. If contacts are closed and 115VAC is present between control switch terminal #5

(R) and neutral (W), check PM capacitor and motor winding continuity.

5c) Initial Harvest Cycle Termination Diagnosis: When the thermistor reaches 48°F (9°C), CB reads 3.9 kΩ from the thermistor and turns harvest termination over to the harvest timer (S4 dip switch 1 & 2). Check discharge line temperature. For a thermistor check, see "II.F. Thermistor Check." If 1-min. fill cycle starts after harvest timer terminates, check that FS is clean and operating properly, see "II.E. Float Switch Check and Cleaning." If FS is closed, CB proceeds to the next cycle. If not, replace CB.

Note: The minimum total time allowed by CB for a complete harvest cycle is 2 min. Maximum harvest time allowed is 20 min.

NOTICE! S4 dip switch 7 must remain on. Otherwise, PM will not energize during the last 50 sec. of harvest.

6)Freeze Cycle – LED 1 is on. Comp, FMR, and PM continue. FM and LLV energize. HGV and X10 relay deenergize. Appliance is held in freeze by a 5-min. short cycle protection timer. After 5-min. timer terminates and FS opens, freeze cycle terminates. Note: PM power supply switches from CB K1 #5 (DBU) in harvest to K1 #4 (R) in freeze.

a)Freeze Cycle Diagnosis: Confirm Comp, FMR, and PM continue. Confirm that

FM and LLV energize. Confirm WRV opens. Next, confirm HGV and X10 relay de-energize. During the first 5 min. of freeze, confirm evaporator is cooling. If not, confirm WV de-energized (not leaking by), HGV de-energized (not bypassing), LLV and FM energize, TXV and HM operate correctly, WRV opens, Comp is efficient, and refrigerant charge is correct. See "VIII.A. Specification and Performance Data."

b)Comp and FMR Diagnosis: If Comp and FMR de-energize once freeze begins, check that appliance has not shut off on HPS ("POWER OK" LED off). If so, check

"3)b) HPS Diagnosis" above. If "POWER OK" LED is on, check for 115VAC at CB K1

#1 (V) or #9 (V) to neutral (W). If 115VAC is not present and LED 1 is on, replace CB. If 115VAC is present, check for 115VAC at CR or MC coil. If 115VAC is present, check

CR or MC coil and contact continuity. Replace as needed. If CR or MC is okay, check Comp start relay and start and run capacitors. Next, check Comp motor winding continuity. If Comp is energized but evaporator is not cooling, check for an inefficient Comp. See "VIII.A. Specification and Performance Data." If Comp is energized but FMR is not, check for 115VAC at the FMR junction box. If 115VAC is not present, check icemaker wiring connections. If 115VAC is present, check for voltage at condenser unit. If 115VAC is not present, check field wiring connections. If 115VAC is present, check FMR capacitor, motor winding, and fan blade for binding.

27

Page 27
Image 27
Hoshizaki SRH/3 KM-2100SWH3, SRH/3 KM-1400SWH-M, SWH3-M KM-1601SAH/3, KM-1301SAH/3, SRH3 KMH-2000SWH/3, SRH3 KM-2500SWH3

SRH/3 KM-1900SAH/3, SRH3 KM-2500SWH3, SRH3 KMH-2000SWH/3, SWH/3, KM-1301SAH/3 specifications

The Hoshizaki KM-1301SRH/3, KM-1301SWH/3, and KM-1301SAH/3 are advanced ice makers designed for commercial use, addressing a wide variety of needs in restaurants, hotels, and bars. These models are known for their efficiency, durability, and innovative technologies that ensure the production of high-quality ice.

One of the standout features of these units is their ability to produce a high volume of ice, reaching up to 1,300 pounds per day, which is crucial for establishments with heavy ice demands. The machines utilize advanced cooling technology, allowing for faster ice production and minimizing the time required to refill ice bins. This makes them ideal for busy settings where speed and efficiency are paramount.

The KM-1301 series employs a unique stainless steel exterior that not only ensures longevity and resistance to corrosion but also enhances the aesthetic appeal of any commercial kitchen or bar. The interior is designed for easy cleaning, helping to maintain hygiene standards vital for food safety.

These ice makers utilize the proprietary Hoshizaki Cubelet Ice system, producing small, chewy ice cubes that are perfect for various beverages and food displays. The advanced design of the ice-making mechanism ensures that ice is formed quickly and efficiently, reducing energy consumption. Additionally, Hoshizaki’s CycleSaver technology optimizes the production process by reducing the amount of water used, making these machines environmentally friendly.

Another characteristic is their self-diagnostic capability, which allows for real-time monitoring of unit performance and quicker troubleshooting, minimizing downtime. The built-in alerts notify operators of any issues or maintenance needs, ensuring that the ice-making process remains uninterrupted.

The KM-1301 series also provides user-friendly controls that allow easy adjustments and monitoring of ice production settings. This flexibility enables businesses to meet varying ice demands based on seasonality or special events.

In summary, the Hoshizaki KM-1301SRH/3, KM-1301SWH/3, and KM-1301SAH/3 ice makers are exemplary choices for commercial ice production. With their high output, durable design, energy efficiency, innovative technologies, and user-friendly features, they cater effectively to the rigorous demands of the foodservice industry while maintaining a commitment to quality and sustainability.