7. KM-1400SWH-M

SPECIFICATION SHEET

 

 

 

 

 

 

 

 

 

AC SUPPLY VOLTAGE

 

208-230/60/1 (2 Wire)

 

 

 

 

AMPERAGE

 

9.7 A ( 5 Min. Freeze AT 104°F / WT 80°F)

 

 

MINIMUM CIRCUIT AMPACITY

 

15 A

 

 

 

 

 

 

 

MAXIMUM FUSE SIZE

 

15 A

 

 

 

 

 

 

 

ELECTRIC & WATER CONSUMPTION

90/70°F

 

 

70/50°F

 

 

 

 

ELECTRIC W (kWH/100 lbs.)

1820(3.4)

 

1800(3.2)

 

 

 

 

POTABLE WATER gal./24HR (gal./100 lbs.)

244(18.9)

 

462(33.7)

 

 

 

 

WATER COOLED CONDENSER

2078(161)

 

1108(81)

 

 

 

 

gal./24HR (gal./100 lbs.)

 

 

 

 

 

 

 

 

 

ICE PRODUCTION PER CYCL 32.5 lbs. (14.7 kg)

1440pcs.

 

 

 

 

 

 

 

REFRIGERANT CHARGE

R404A, 2 lb. 2.4 oz. (975g)

 

 

 

 

 

 

 

PERFORMANCE SHEET

 

 

 

 

 

 

 

 

 

APPROXIMATE ICE

 

AMBIENT TEMP.

 

 

WATER TEMP. (ºF/ºC)

 

 

PRODUCTION PER 24 HR.

 

(ºF/ºC)

50/10

 

 

70/21

 

 

 

90/32

 

 

 

 

 

70/21

1370

621

 

1347

611

 

1252

568

 

 

 

 

 

80/27

1353

614

 

1318

598

 

1186

538

lbs./day

 

kg./day

 

 

90/32

1347

611

 

1293

587

 

1175

533

 

 

100/38

1307

593

 

1265

574

 

1066

484

 

 

 

 

 

 

 

 

 

 

 

APPROXIMATE ELECTRIC

 

70/21

1800

 

 

1806

 

 

 

1843

CONSUMPTION

 

80/27

1804

 

 

1814

 

 

 

1866

 

 

 

 

 

90/32

1806

 

 

1820

 

 

 

1867

watts

 

 

 

 

100/38

1823

 

 

1831

 

 

 

1910

APPROXIMATE WATER

 

70/21

1570

5.94

 

1790

6.78

 

2334

8.84

CONSUMPTION PER 24 HR.

 

80/27

1738

6.58

 

2080

7.88

 

2759

10.44

gal./day

 

m3/day

 

90/32

1790

6.78

 

2322

8.79

 

2955

11.19

 

 

100/38

2226

8.42

 

2471

9.35

 

3537

13.39

FREEZING CYCLE TIME

 

70/21

30

 

 

31

 

 

 

33

 

 

 

 

 

80/27

31

 

 

32

 

 

 

35

 

 

 

 

 

90/32

31

 

 

33

 

 

 

36

min.

 

 

 

 

100/38

32

 

 

34

 

 

 

39

HARVEST CYCLE TIME

 

70/21

3.9

 

 

3.6

 

 

 

3.5

 

 

 

 

 

80/27

3.7

 

 

3.2

 

 

 

3.3

 

 

 

 

 

90/32

3.6

 

 

2.8

 

 

 

2.9

min.

 

 

 

 

100/38

3.3

 

 

2.8

 

 

 

2.9

HEAD PRESSURE

 

70/21

220

15.5

 

229

16.1

 

249

17.5

 

 

 

 

 

80/27

227

15.9

 

240

16.9

 

265

18.7

PSIG

kg/cm2G

 

90/32

229

16.1

 

250

17.6

 

273

19.2

 

100/38

236

16.6

 

255

18.0

 

295

20.7

SUCTION PRESSURE

 

70/21

50

3.5

 

51

3.6

 

55

3.9

 

 

 

 

 

80/27

51

3.6

 

53

3.8

 

58

4.1

PSIG

kg/cm2G

 

90/32

51

3.6

 

55

3.9

 

59

4.2

 

100/38

53

3.7

 

56

3.9

 

63

4.4

TOTAL HEAT OF REJECTION FROM CONDENSER

22,800

BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

TOTAL HEAT OF REJECTION FROM COMPRESSOR

2,500

BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

WATER FLOW FOR CONDENSER

138 gal./h [AT 100ºF (38ºC) / WT 90ºF (32ºC)]

PRESSURE DROP OF COOLING WATER LINE

less than 10 PSIG