Hoshizaki SRH/3 KM-2100SWH3 G Control Board with Harvest Pump Timer Operation Flow Chart

Models: SRH/3 KM-1900SAH/3 SRH3 KM-2500SWH3 SRH3 KMH-2000SWH/3 SWH/3 KM-1301SAH/3 SWH3-M KM-1601SAH/3 SRH/3 KM-1400SWH-M SRH/3 KM-2100SWH3 SRH/3

1 101
Download 101 pages 53.65 Kb
Page 18
Image 18
"G" Control Board with Harvest Pump Timer Operation Flow Chart

"G" Control Board with Harvest Pump Timer Operation Flow Chart

 

 

 

 

 

 

1. 1-Minute

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cycle

 

 

 

 

 

 

2. Harvest Cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3. Freeze Cycle

 

 

 

4. Pump-Out Cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Steps

 

 

 

Fill Cycle

 

 

• WV time: 6 min. or the length of harvest minus 50

 

 

 

• Min. freeze time: 5 min.

 

 

• Factory set for every

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

sec. (S4 dip switch 7), whichever is shorter. Do not

 

 

• Max. freeze time: freeze timer setting

10th cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

adjust S4 dip switch 7 out of the factory position.

 

 

 

(S4 dip switch 9 & 10)

 

 

(S4 dip switch 5 & 6)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Max. harvest time: 20 min.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Pump motor stops for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 sec., then reverses

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thermistor

 

 

 

1 to 3-min. harvest timer in

 

 

 

 

 

 

 

5-min. timer

 

 

 

 

 

 

for 10/20 sec.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(S4 dip switch 3 & 4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FS in control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

in control

 

 

 

 

 

 

control (S4 dip switch 1 & 2)

 

 

 

 

 

 

in control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Harvest Pump

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Timer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Startup

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50 sec.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FS check

 

 

 

FS closed

 

 

 

 

 

PM energized

 

FS check

 

 

 

FS closed

 

 

 

FS opens or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WV de-energized

 

 

 

Comp continues

 

Comp continues

 

 

 

 

 

 

 

 

WV energized

 

 

Comp energized

 

 

 

 

 

 

 

 

 

 

 

 

 

 

freeze timer

 

 

 

 

 

 

 

 

 

 

Thermistor temperature

 

 

 

 

 

 

 

 

 

 

 

FMR continues

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FM continues

 

terminates

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FMR energized

reaches 48°F (9°C)

 

 

 

 

 

 

 

 

 

 

 

HGV energized

 

 

 

 

 

 

 

 

 

 

 

 

FS open

 

 

HGV energized

 

 

 

 

 

 

 

 

 

 

FMR continues

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(3.9 kΩ or less).

 

 

 

 

 

 

 

 

 

 

 

 

 

PM de-energizes for 2 sec.,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WV energized

 

 

 

 

 

 

 

 

 

 

PM continues

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Harvest timer starts.

 

FS open

 

 

 

 

 

then reverses for 10/20 sec.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LLV energized

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HGV de-energized

 

 

 

FM de-energized

 

 

 

 

 

 

 

 

 

If FS is open, Comp stops and cycle returns to 1-Min. fill.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(FM continues on KM-1601SAH)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LLV de-energized

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shutdown

 

 

 

1. Bin Full

 

 

 

 

 

 

 

 

 

 

 

 

2. Icemaker Off

 

 

3. Ice Level Lowered

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and Restart

 

 

 

 

 

Within 10 sec. after ice contacts BC bulb,

 

All components

 

 

 

 

 

 

No ice touching BC bulb.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

icemaker shuts down.

 

 

 

 

 

de-energized.

 

 

 

 

 

 

Icemaker starts at

 

 

 

 

 

 

BC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

"1. 1-Minute Fill Cycle."

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To 1. 1-Minute Fill Cycle

Operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. "G" Control Board with Harvest Pump Timer Operation

Ice contacts BC bulb

Legend:

BC–bin control Comp–compressor FM–fan motor FMR–fan motor-remote FS–float switch HGV–hot gas valve LLV–liquid line valve PM–pump motor WV–inlet water valve

BC open

BC closed

All components

NOTE: Green "BC CLOSED" LED on continuously

de-energized

when the K4 jumper is in place.

 

Components Energized when the Control Switch is in the "WASH" Position

The "WASH" position on the control switch is used when cleaning and sanitizing the unit. When in the "WASH" position, power is supplied to the pump motor. With the cleaning valve closed, the cleaner and sanitizer flow over the outside of the evaporator plate assembly. With the cleaning valve open, the cleaner and sanitizer flow over both the outside and the inside of the evaporator plate assembly.

Note: Close the cleaning valve after cleaning and sanitizing are complete, otherwise the unit will not restart when the control switch is placed in the "ICE" position.

Page 18
Image 18
Hoshizaki SRH/3 KM-2100SWH3, SRH/3 KM-1400SWH-M, SWH/3 G Control Board with Harvest Pump Timer Operation Flow Chart