Hoshizaki SRH3 KM-2500SWH3, SRH/3, SWH/3 B. LED Lights and Audible Alarm Safeties, E Control Board

Models: SRH/3 KM-1900SAH/3 SRH3 KM-2500SWH3 SRH3 KMH-2000SWH/3 SWH/3 KM-1301SAH/3 SWH3-M KM-1601SAH/3 SRH/3 KM-1400SWH-M SRH/3 KM-2100SWH3 SRH/3

1 101
Download 101 pages 53.65 Kb
Page 43
Image 43

B. LED Lights and Audible Alarm Safeties

1. "E" Control Board

At startup, a 5-second delay occurs while the control board conducts an internal timer check. A beep occurs when power is turned off. The red "POWER OK" LED indicates proper control voltage and remains on unless a control voltage problem occurs. The green LEDs 1 through 4 energize and sequence from initial startup as listed in the table below. Note that the order of the LEDs from the outer edge of the control board is 1, 4, 3, 2.

Sequence Step

LED

Energized

 

Time LEDs are On

Components

Min.

 

Max.

Avg.

 

 

 

1-Minute Fill Cycle

4

WV

 

 

 

1 minute

Harvest Cycle

1, 4, 2

Comp, FMR, HGV, WV

2 minutes

 

20 minutes

3 to 5 minutes

Freeze Cycle

1

Comp, FM/FMR, PM,

5 minutes

 

freeze timer

30 to 35 minutes

 

 

LLV

 

 

setting

 

Pump-Out Cycle

1, 4*, 3, 2

Comp, FMR, HGV, PM,

10 seconds

 

20 seconds

*pump-out timer

 

 

WV*

 

 

 

 setting

The built in safeties shut down the icemaker and have alarms as listed below.

No. of Beeps

Type of Alarm

Notes

(every 3 sec.)

 

 

1

High Evaporator Temp.

Check for harvest problem (stuck HGV or relay), hot

 

(temperature > 127°F) (53°C)

water entering icemaker, or shorted thermistor.

2

Harvest Backup Timer

Orange "H TIMER" LED on.

 

(harvest > 20 min. for two cycles

Check for open thermistor, HGV not opening, TXV or

 

in a row)

LLV leaking by, low charge, or inefficient Comp, or WRV

 

 

leaking by.

3

Freeze Timer

Yellow "F TIMER" LED on.

 

(freeze > specified setting for

Check for FS stuck closed (up), WV leaking by, HGV

 

two cycles in a row)

leaking by, PM not pumping, TXV not feeding properly,

 

 

LLV not opening, low charge, HM not bypassing, or

 

 

inefficient Comp.

To reset the above safeties, press the "ALARM RESET" button with the power supply on.

6

Low Voltage

Red LED turns off if voltage protection operates.

 

(92Vac±5% or less)

The control voltage safeties automatically reset when

7

High Voltage

voltage is corrected.

 

(147Vac±5% or more)

 

Legend: Comp–compressor; FM–fan motor; FMR–fan motor remote; FS–float switch; HGV–hot gas valve; HM–headmaster (C.P.R.); LLV–liquid line valve; PM–pump motor; TXV–thermostatic expansion valve; WRV–water regulating valve; WV–inlet water valve